NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

WTC Emergency Site Health Monitoring – memo

Machine-extracted title · confidence 41%

Comments on air monitoring for confined spaces at WTC site, Oct 2001 draft.

NYC-WTC_000317718
Page image
Scanned page image, NYC-WTC_000317718
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

•OCT-01-2301 NON 01:52 PN NlOSH/R-11 FAX NO. 5134587147 P, 02

Comments on the WTC Emergency Site Health Monitoring and Sampling REP (10/1/01)

1. Recommend including a section detailing any required air monitoring in conjunction with a confined space entry program at tlie WTC site. This information could be included in the section entitled “Additional Site Monitoring Requirements”.

2. R ecommend using NIOSH Method 7300 (sample analysis by inductively coupled plasma- atomic emission spectroscopy) to sample for 27 different elements, including lead. This would provide more detailed information on exposures to airborne metals at the site.

3. NIOSH ha-s not collected any personal or area air samples for formaldehyde at the WTC site, so I am unaware of the rational behind this sampling proposal. However, if this sampling is to be conducted, I would .suggest a more comprehensive analysis for a variety of aldehydes, including acetaldehyde, formaldehyde, and furfural. The sampling collection and analysis method would be similar to just measuring formaldehyde.

4. I would suggest eliminating the total dust/crystallinc silica analysis for the break area. Sampling for respirable dusbcry'stalline silica would be sufficient.

5. 1 am unclear of the need for monitoring for BTEX since these same compounds (benzene, toluene, ethyl benzene, and xylene) can be included in the aromatic hydrocarbons analysis. I addition, 1 am unclear Avhat tasks are included in the designation “Operators” for the BTEX monitoring (heavy equipment operators?).

6. Since concern over potential worker exposures to Freon, phosgene, and hydrogen sulfide have periodically arisen over the past several weeks, I would suggest expanding the WTC Sampling Requirements table shown at the end of the document to include as many of these substances as possible. The sampling frequency could be “as needed” and include some guidance on sample collection (for example, colorimetric detector tubes).

OCT.;?.-. '01 W.ON; 14:46 COW.UXICXTION No:31 PAGE. 2

CITY_21MC100_003049707

NYC-WTC_000317718

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000317718Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000267551

Comments and recommendations on air monitoring methods for WTC site health program.

Similar indexed content

NYC-WTC_000407824

Comments on WTC site health monitoring and sampling plan, including air monitoring and analytical methods.

Similar indexed content

NYC-WTC_000407825

Tabulated sampling plan for workers and responders; targets metals, asbestos, and related exposures.

Similar indexed content

Compare copies and versions →