OCT-O 1-2001 HON 01:52 PH HiOSH/P.-ll ,X NO. 513458714.'

Comments on the WTC Emergency Site Health Monitoring and Sampling REP (lO/i/01)

1. Recommend including a section detailing any required air monitoring in conjunction with a confined space entry program at the WTC site. This information could be included in the section entitled “Additional Site Monitoring Requirements”.

2. Recommend using NIOSH Method 7300 (sample analysis by inductively coupled plasma- atomic emission spectroscopy) to sample for 27 different elements, including lead. This would provide more detailed information on exposures to airborne metals at the site.

3. NIOSH has not collected any personal or area air samplc.s for formaldehyde at the WTC site, so I am unaware of the rational behind this sampling proposal. However, if this sampling is to be conducted, I would .suggest a more comprehensive analysis for a variety' of aldeliyde.s, including acetaldehyde, formaldehyde, and furfural. The sampling collection and analysis method would be similar to just measuring formaldehyde.

4. 1 would suggest eliminating the total dust/crystalline silica analysis for the break area. Sampling for respirable dusbcrystalline silica would be sufficient.

5, 1 am unclear of the need for monitoring for BTEX since these same compounds (benzene, toluene, ethyl benzene, and xylene) can be included in the aromatic hydrocarbons analysis. 1 addition, I am unclear what tasks are included in tire designation “Operators” for the BTEX monitoring (heavy equipment operators?).

6. Since concern over potential worker exposures to Freon, phosgene, and hydrogen sulfide have periodically arisen over the past several weeks, I would suggest expanding the WTC Sampling Requirements table shown at the end of rhe document to include as many of these .substances a.? possible. The sampling frequency could be ‘'as needed” and include .some gLiidance on sample collection (for example, colorimetric detector lubes).

CITY_21MC100_003572805

NYC-WTC_000267539

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000267539Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000280660

Additional pages for the WTC health monitoring and sampling RFP, city file reference.

Similar indexed content

NYC-WTC_000317719

SOW describing general site exposure monitoring for WTC demolition/repair work.

Similar indexed content

NYC-WTC_000188121

Request for Proposal document from October 1, 2001, regarding health monitoring and sampling at the World Trade Center emergency site.

Similar indexed content

NYC-WTC_000280647

Doc header for health monitoring and sampling RFP, 10/01/01, contract file.

Similar indexed content

Compare copies and versions →