Dioxin. Ambient air samples exceeded EPA’s screening criteria (see Appendix B) at various
sampling stations during September and October. Data trend analysis for dioxin in ambient air
[EPA, 2002a and Lioy, 2002] showed that concentrations significantly exceeded the risk-based
screening level of 0.001 - 0.005 ng/m’. This range was based on an excess lifetime cancer risk of
1 X lO”^ over a 30 year exposure duration for residential settings, using both the existing cancer
Slope Factor [Integrated Risk Information System (IRIS), 2002] and proposed cancer Slope
Factor in EPA’s draft dioxin reassessment [EPA, 2001].iTherefore, dioxin (and related
congeners) is included as a COPC.
Building Materials (Asbestos, Fibrous Glass, Crystalline Silica)
The evaluation of building materials for inclusion as COPCs required a different approach than
that used for the combustion by-products. Those compounds (PAHs, dioxin) benefit from
consensus toxicity criteria (i.e., IRIS verified cancer Slope Factors) that allows for a quantitative
screening paradigm. With the exception of asbestos, the building materials evaluated (including
fibrous glass, crystalline silica, mica, portlandite, calcite and gypsum) do not have IRIS verified
inhalation toxicity criteria from which to perform quantitative risk assessment. Complicating
this matter is the knowledge that many of these substances were deposited in a large cloud from
the collapse of the towers. Thus, the settled dust may serve as a reservoir for re-suspension and
eventual inhalation exposure. In addition, materials such as fibrous glass can also cause contact
irritation when exposed directly to the skin.
The potential for exposure to building materials in the indoor environment was assessed by
reviewing sampling data on the constituent composition of the indoor/outdoor bulk dust and
indoor/ambient air [EPA 2002c, USGS 2001, ATSDR/NYCDOH Indoor Air Sampling
Program] With the exception of asbestos, the extremely limited air sampling data for specific
building constituents in indoor air dictated that an assessment approach had to be based on
historical data relating the concentration of fibers in air (fibers per cubic centimeters or f/cc) to
the load in settled dust (fibers per square centimeters or f/cm^) [Millette and Hays 1994]
Although the empirical relationships (called K factors) are not rigorous enough to rely on for a
firm health decision, they are used in this report to define what might constitute elevated building
material counts that would need to be addressed on a near-term basis. This approach may
overestimate potential exposures but, as such, is protective.
Toxicity criteria for building materials (with the exception of asbestos) were obtained from
occupational sources, such as the Occupational Safety and Health Administration’s permissible
exposure limits (OSHA PELs), and the American Conference of Governmental Industrial
Hygienists threshold limit values (ACGIH TLVs). The evaluation of exposure potential coupled
with toxicity information identified three COPCs (asbestos, fibrous glass and crystalline silica).
Asbestos. In the days immediately following the disaster, EPA analyzed the settled bulk
dust/debris for asbestos content. More than one third of the approximately 150 samples
3