NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 21 pages

WTC COPCs assessment draft, indoor health risks

Machine-extracted title · confidence 56%

Draft COPCs selection and discussion of indoor environmental risks post-9/11.

NYC-WTC_000317656–000317676
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

The list of COPCs is shown in the column at the left, below. Included for each COPC is a data summary that supports its inclusion on the list. For completeness, an additional list is included on the right containing substances that, for various reasons, have created concern, but on closer inspection, were either rarely detected in the ambient air sampling around the WTC, or routinely found at concentrations below the health-based screening criteria presented in Appendix B.

COPCs Other Substances Lead Benzene PAHs PCBs Dioxin Chromium Asbestos Cadmium Fibrous Glass Manganese Crystalline Silica Mercury Particulate Matter Refractory Ceramic Fibers Mold

Lead and Combustion By-Products (PAHs, Dioxin)

Lead. EPA’s ambient air monitoring data detected lead in concentrations that exceeded the National Ambient Air Quality Standard (NAAQS) for lead on five occasions from September 18- 27, 2001. It should be noted that the NAAQS for lead is based on a three-month average. Since the ambient monitoring program began, no three-month average of the ambient air data for lead exceeded the NAAQS of 1.5 ug/m’. However, lead was more commonly found at concentrations that exceeded 0.1 ug/m\ the default value employed in EPA’s Integrated Exposure Uptake/Biokinetic Model for Lead in Children [EPA, 1994], This value represent the upper­ bound of average airborne lead concentrations in urban environments. Additional support for including lead as a COPC was provided by a report that characterized the dust that settled over lower Manhattan after the WTC collapse [Lioy, 2002]. The lead concentration in settled dust ranged from 101 - 625 parts per million (ppm). By itself, this range does not represent extraordinarily high concentrations, but in combination with the mass of material released from the collapse of the towers, it represents a potentially significant increase in the mass of lead deposited in lower Manhattan. Therefore, lead is included as a COPC. t PAHs. Limited ambient air sampling was conducted for PAHs during the period of time (September through December) when combustion processes were occurring at the site.. However, concentrations in bulk dust [EPA, 2002a and Lioy, 2002] exceeded the removal guidelines for soil in EPA’s Hazard Evaluation Handbook [EPA, 1997] of 9 ppm based on benzo(a)pyrene equivalents. This value is risk-based equating to an excess lifetime cancer risk of 1x10-^ over a 30-year exposure duration for residential settings. Therefore, PAHs are included as a COPC.

2

CITY_21MC100_008969674

NYC-WTC_000317657

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000317657Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →