NYC 9/11 Public Portal Document
Crystalline silica - respirable fraction of alpha-quartz
Tier Action Crystalline Silica (settled dust) Crystalline Silica (indoor air)
Level Basis Level Basis
I Aggressive cleaning. If 5.0/2g/m^ * OSHA PEL of
levels persist, take 50 /2g/m’ (see
additional action to narrative
reduce exposure. below).
Evaluate conditions in
the area including
representativeness of
air samples, asbestos
settled dust levels and
loading.
II Maintain recommended above 5.0 /xg/m’ to
cleaning methods. background 0.5 /2g/m’ (or
Consider additional background)
monitoring. *
Evaluate conditions in
the area including
representativeness of
air samples, fibrous
glass settled dust levels
and loading.
III No further action background Level is set at 0.5 /2g/m^ or OSHA PEL of
required. that found in background 50 /zg/m’ (see
background, or narrative
unaffected, areas. below).
In this way, no
increase in risk
due to the silica
in settled dust
would be
expected.
* Silica measured in airborne respirable dust, by NIOSH 7500.
<Need to explain why no Tier I vtduefor settled dust>
The Tier I level of silica in indoor air was based on the Occupational Safety and Health
Administration’s (OSHA) permissible exposure limit (PEL) for respirable silica in air of
18
CITY_21MC100_0 08969690
NYC-WTC_000317673