NYC 9/11 Public Portal Document
Crystalline silica - respirable fraction of alpha-quartz
Tier Action Crystalline Silica (settled Crystalline Silica (indoor air)
dust)
Level Basis Level Basis
I Aggressive cleaning. If 5.0/2g/m^ * OSHA PEL of
levels persist, take 50 (see
additional action to narrative
reduce exposure. below).
Evaluate conditions in
the area including
representativeness of
air samples, asbestos
settled dust levels and
loading.
n Maintain recommended above 5.0 /2g/m^ to
cleaning methods. background 0.5 A^g/m’ (or
Consider additional background)
monitoring. *
Evaluate conditions in
the area including
representativeness of
air samples, fibrous
glass settled dust levels
and loading.
in No further action background Level is set at 0.5 Mg/m^ or OSHA PEL of
required. that found in background 50 Aig/m^ (see
background, or narrative
unaffected, areas. below).
In this way, no
increase in risk
due to the silica
in settled dust
would be
expected.
* Silica measured in airborne respirable dust, by NIOSH 7500.
The Tier I level of silica in indoor air was based on the Occupational Safety and Health
Administration’s (OSHA) permissible exposure limit (PEL) for respirable silica in air of
50 Aig/m’ as a time weighted average for an 8 hour exposure. The PEL was divided by a factor of
20