Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
factor for a worst case scenario of a high level of activity. Although K factors are based on
activity data for asbestos, they are believed to be protective for fibrous glass, which is larger and
less airborne. In addition, although K factors are not rigorous enough to rely upon for a firm
health decision, they are used here only to define what might constitute elevated fiber counts,
that would need to be addressed as a near-term concern. This approach may overestimate
potential exposures, but as such, is protective.
The Tier I level for fibrous glass in indoor air was based on the American Conference of
Governmental Industrial Hygienists* (ACGIH) threshold limit value (TLV) of 1 f/cc. That TLV
is based on limiting irritant effects of fibrous glass on workers. The TLV was divided by a factor
of ten to account for the different exposure durations between ACGIH’s workers and the WTC
area’s residents.
The Tier III level for fibrous glass in indoor air was based on the ACGIH TLV of 1 f/cc, divided
by a factor of 100 to account for the different sensitivities between ACGIH’s healthy works and
the WTC area’s more varied population.
17
CITY_21MC100_0 08969689
NYC-WTC_000317672
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000317672Source: NYC Law Department, mirrored locally