WTC monitoring chart: asbestos method overview

Machine-extracted title · confidence 39%

Monitoring page detailing asbestos testing methods and parameters.

NYC-WTC_000317655
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z ■<

o io WTC Indoor Air Monitoring - Sampling and Analytical Procedures Analytical I Media Sampling Points Sampling Method Proposed Sampling Vulnerability/Practicalily Analytical Method Proposed

1 o Parameters o o 'This lest method does not describe procedures or techniques o required to evaluate the safety or habitability of buildings with CD cn cn Asbestos MicrovacASTM 5755-95 asbestos-containing materials, or compliance with federal, slate, or local regulations or statutes. It is the user's responsibiKty to make these determinations." (Section 5.1.1 of method 5755-95) ASTM 5755-95 1 Lead MicrovacASTM 5755-95“ NIOSH 7300 Carpets, fabric fumtture or Porous Soft After speaking with several people in HQ and RTP, it does not appear drapery in areas of activity Still checking on methods. Reached surfaces there are standardized methods for the collection of these To be determined once the sampling method (if (living rooms, family rooms) Dioxins out to RTP and HQ. Waiting for parameters, rather many of the methods being used today are any) has be selected additional information research and development procedures. PAHs

Silica See the comment for asbestos. Samples will be combined with the MMVF Microvac ASTM 5755-95 EMSL MSD.0300 asbestos sampling.

This test method does not describe procedures or techniques required to evaluate the safety or habitability of buildings with Wipe ASTM D 6480-99 or ASTM D 6480-99 (wipe) or Asbestos asbestos-containing materials, or compliance with federal, state, or Microvac ASTM 5755-95 ASTM 5755-95 (microvac) local regulations or statutes. It is the user's responsibility to make these determinations." (Section 5.1.1 of method 5755-95) Horizontal surfaces of tables Non-porous or counters and barefloors, Lead NIOSH 9100 None known, wipe sampling has been legally defended. SW-846 6010B Hard ceilings and walls in areas surfaces of activity (living rooms, Dioxins ASTM D 6661-01 ASTM 6661-01/SW-846 8290 family rooms) PAHs ASTM D 6661-01 ASTM 6661-O1/SW-846 8270C

Silica See comment for silica above. See comment for silica above. See comment for silica above. Wipe ASTM D 6480-99 or Same as asbestos microvac. Samples will be combined with the MMVF EMSL MS0.O3O0 Microvac ASTM 5755-95 asbestos sampling. Air pump operated at lOL/min for 8 hours to achieve the PIC wkgroup PCM NIOSH 7400 followed by TEM AHERA Asbestos NIOSH 7400 detection limits method. Air pump operated at lOUmin for 8 hours to achieve the PIC wkgroup Lead NIOSH 7300 SW-846 6010B Areas of known activity detection limits Indoor Air (living rooms, family rooms) Air pump operated at 2.5L/min for 8 hours to achieve the PIC o Silica NIOSH 7500 NIOSH 7500 (XRD) wkgroup detection limits H Assumed that it behaves the same as asbestos, samples will be MMVF NIOSH 7400 EMSL MSD.0300 combined with the asbestos sampling. S NOTE: All samples (cassettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the laboratory will weigh the o sample wipe or cassette prior to performing the analysis. o o I " This method is for asbestos and is being modified for the collection of lead dust. Modification - to use the filter specified for method NIOSH 7300 o o co wo wo coo cn coo

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000317655Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →