/ Method 8290 Analysis Results
Client - ATC
Client's Sample ID ATC-0427-STY-DX1
Lab Sample ID 103513461
Filename F20524A_11
Injected By MRO
Total Amount Extracted 0.38 g Matrix DUST
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/27/2002
ICAL Date 05/04/2002 Received 05/01/2002
CCal Fil6name(s) F20524A_01 & F20524A_15 Extracted 05/20/2002
Method Blank ID BLANK-1633 Analyzed 05/24/2002 17:26
Native Cone EMPC LRL Internal ng's Percent
isomers ng/Kg ng/Kg ng/Kg Standards Added Recovery
2.3,7.8-TCDF 38 5.3 E 2,3.7,8-TCDF-13C 2.00 72
Total TCDF 500.0 5.3 2.3,7,8-TCDD-13C 2.00 70
1,2,3,7,8-PeCDF-13C 2.00 68
2,3.7.8-TCDD 9.5 5.3 J 2,3,4,7,8-PeCDF-13C 2.00 72
Total TCDD 1000.0 5.3 1,2.3,7,8-PeCDD-13C 2.00 77
1,2,3,4.7,8-HxCDF-13C 2.00 61
1,2,3,7,a-PeCDF 41.0 26.0 J 1,2,3,6,7,a-HxCDF-13C 2.00 62
2,3,4,7.a-P6CDF 64.0 26.0 J 2.3,4,6,7,8-HxCDF-13C 2.00 83
Total PeCDF 450.0 26.0 1,2,3.7.8,g-HxCOF.13C 2.00 50
1,2,3,4,7,8-HxCDD-13C 2.00 85
1,2,3.7.8-P9CDD ND 26.0 1,2,3.6,7,8-HxCDD-13C 2.00 90
Total PeCDD 500.0 26.0 1,2,3,4,6,7.8-HpCDF-13C 2.00 61
1.2,3,4.7,8,9-HpCDF-13C 2,00 39 IP
1.2,3,4,7,8-HxCDF 54.0 26.0 J 1.2,3,4,6,7,8-HpCDD-13C 2.00 52
1.2,3,6,7,8-HxCDF S3 26.0 E OCDD-13C 4.00 47
2,3.4,6,7,8-HxCDF 77.0 26.0 J
1.2.3,7,8,9-HxCDF 78 26.0 I 1.2,3.4-TCDD-13C 2.00 NA
Total HxCDF 620.0 26.0 1.2,3,7,8.9-HxCDD-13C 2.00 NA
1,2,3.4,7,8-HxCDD 30.0 26.0 J 2,3.7,8-TCDD-37Cl4 0.20 72
1,2.3,6,7,8-HxCDD 49.0 26.0 J
1,2,3,7,8.9-HxCDD 43.0 26.0 J
Total HxCDD 970.0 26.0
1,2.3,4,6,7,8-HpCDF 340.0 26.0 Total 2.3,7.8-TCDD
1.2,3,4,7,8,9-HpCDF ND 32.0 A Equivalsnca: 82 ng/Kg
Total HpCDF 340.0 26.0 (Using ITE Factors)
1,2,3.4,6,7.8-HpCDD 540.0 26.0
Total HpCDD 900.0 26.0
OCDF 380.0 53.0
OCDD 3900,0 53.0
Results reported on a total weight basis LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,3-substitLrtea isomers) 1 = Interference
EMPC = SiSmatsd Maximum Possible Concentration E = PCDE imertorBncB
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less Tian 10 times nigher than mettiod blank level NA = Not Applicaole
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1057132