NYC 9/11 Public Portal Document
1700 Brn Street - Sufte 200
Minneapolis, MN 55414
^ace Analytical__________ Method 8290 Analysis Results
Tai: 612-607-1700
Fav (512-
/
Client - ATC
Client’s Sample ID ATC-0427-STY-DX2
Lab Sample ID 103513479
Filename F20524A 12
Injected By MRO
Total Amount Extracted 0.17 g Matrix DUST
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/27/2002
ICAL Date 05/04/2002 Received 05/01/2002
CCal Filename(s) F20524A_01 &F20524A_15 Extracted 05/20/2002
Method Blank ID BLANK-1633 Analyzed 05/24/2002 18:16
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/Kg ng/Kg ng/Kg Standards Added Recovery
2,3,7.8-TCDF — 160 15.0 EA 2,3,7.8-TCDF-13C 2,00 74
Total TCDF 3200 12.0 2.3,7,8-TCDD-13C 2.00 73
1,2,3,7,8-PeCDF-13C 2.00 72
2,3,7,8-TCDD 26 12.0 J 2.3,4.7,8-PeCDF-13C 2.00 73
Total TCDD 3800 12.0 1.2,3,7,8-PeCDD-13C 2.00 78
1,2,3,4.7,a-HxCDF-13C 2.00 69
1,2,3,7,8-PeCDF 150 59.0 E 1,2,3,6,7.8-HXCDF-13C 2.00 79
2,3,4,7.8-PeCDF 200 59.0 J 2.3.4,6,7,a-HxCDF-13C 2,00 78
Total PqCDF 1400 59.0 1,2,3,7,8.9-HxCDF-13C 2.00 57
1,2,3,4,7,8-HxCDD-13C 2.00 87
1,2.3,7,8-P8CDD ND 59.0 1,2,3,6.7,8-HxCDD-13C 2.00 92
Total PeCDD 1500 59.0 1,2.3,4,6,7,8-HpCDF-13C 2.00 64
1,2,3,4,7,8.9-HpCDF-13C 2.00 45
1,2,3,4,7,8-HxCDF 170 59.0 J 1,2,3,4,6,7,8-HpCDD-13C 2.00 44
1,2,3,6,7,8-HxCDF 240 59.0 E OCDD-13C 4.00 45
2,3,4,6,7,8-HxCDF 190 59.0 J
1,2,3,7.8,9-HxCDF ND 59.0 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 1600 59.0 1,2,3,7.8.9-HxCDD-13C 2.00 NA
1,2,3,4.7,8-HxCDD ND 59.0 2,3,7,8-TCDD-37CI4 0.20 75
1,2,3,6,7,8-HxCDD 110 59.0 J
1,2,3,7,8.9-HxCDD 79 59.0 J
Total HxCDD 1900 59.0
1.2,3.4,6,7,a-HpCDF 900 59.0 Total 2,3.7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 90.0 A Equivalence: 220 ng/Kg
Total HpCDF 900 59.0 (Using ITE Factors)
1,2.3,4,6,7,a-HpCDD 1300 59.0
Total HpCDD 3000 59.0
OCDF 1200 120.0
OCDD 12000 120.0
Results reported on a total weight basis LRL = Lower Reporting Limit
Cone = ConcanJration (Totals include 2,3,7,8-3ubstlnjted Isomsrs) I = Intarferanca
EMPC = estimated Maximum Possible Concentration E G PCDE Interference
A = Detection Umit based on slgna)-to-noise measurement S = Saturated signal
J - Concentration detected is below the calibration range ND = Not Detectad
B = Less tban 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained ‘ram additional analysis • = See Discussion
Report No.... 02-1057132
REPORT OF LABORATORY ANALYSIS
This rsport shall not be reproduced, except in full,
without Iha written consent of Paca Analytical Services, Inc.
CITY_21MC100_003049267