Mr. Bernard P. Orlan April 19, 2002 Indoor Air Quality Assessment Page 3 P. S. 89M ATC Project No. 15-19125-0297
Real-Time Environmental Measlrements
ATC collected eighty (80) sets of real-time environmental measurements consisting of seventy (70) from inside the school building and ten (10) from outdoors. All five floors of the school building were surveyed. These results are described below.
Field data sheets are found in Attachment 1. Readings began at 8:00 A.M. and concluded at approximately 11:300 A.M.
Temperature
Indoor dry bulb temperature measurements ranged from 73 °F to 82.4 °F. One (1) of the indoor measurements for temperature were above and sixty nine (69) were within the range of 73 to 79°F (at 50 percent relative humidity) as recommended by the ASHRAE Standard 55-1992 during the summer season . The outdoor temperature measurements ranged from 80.3 °F to 81.6 °F.
Jielative /Tumidity
Idle relative humidity indoors ranged from 38.5 to 51.3 percent. All of the indoor measurements for relative humidity were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements ranged from 43.1 to 46.3 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 532 ppm to 1351 ppm. Three (3) of the indoor measurements were above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. ITie maximum outdoor (background) C;:O2 concentration was 552 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1252 ppm (background level -I- 700 ppm). The highest concentrations were detected in Room # 510 (1351ppm with 31 occupants),Room # 432 (1280 ppm with 35 occupants), and Room # 402 (1280 ppm with 31 occupants).Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outside makeup air. The primary/ source of CO2 indoors is occupant respiration. The school building was occupied during ATC’s assessment.
Cgr^nMp^xide Concmtration
(/arbon monoxide concentrations indoors ranged between 2 ppm to 3 ppm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentration was 4 ppm for all collected readings.
Respirable Particulates (PM2j)
Respirable particulate concentrations* indoors ranged between 14 pg/m^ to 38 ug/m^. The average PM2.5 concentration for the entire school building was approximately 26 g/m^. All the indoor measurements were bellow the NPAAQS of 65 pgnC 24-hour average concentration of
CITY_21MC100_006739444
NYC-WTC_000313502
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000394433
Formal report of IAQ measurements collected at P.S. 89M in April 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392649
IAQ report for April 18, 2002 at PS 89M; BOE requested evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369326
IAQ measurements collected June 20, 2002 for PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370089
ATC IAQ measurements conducted June 20, 2002 at PS 89M for BOE.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313646
ATC IAQ measurements at PS 89M for May 13-14, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000394421
Indoor air quality report for P.S. 89M with April 16, 2002 measurements.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392637
ATC IAQ measurements report dated April 17, 2002; school air quality evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369789
ATC IAQ measurements at PS 89M for BOE; May 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369736
ATC IAQ measurements report for PS 89M, May 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328289
Indoor air quality measurements collected on April 18, 2002 for PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392840
ATC IAQ report of measurements collected May 13, 2002 at PS 89M for BOE.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313893
ATC IAQ measurements collected June 18, 2002 at PS 89M per BOE request.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000394433
Formal report of IAQ measurements collected at P.S. 89M in April 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328289
Indoor air quality measurements collected on April 18, 2002 for PS 89M.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313593
ATC measures temperature and basic IAQ parameters at PS 89M for BOE in May 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369723
ATC IAQ measurements at PS 89M for BOE, May 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392768
ATC report of IAQ measurements collected May 3, 2002 at the school.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328327
ATC reports IAQ measurements at PS 89M, 201 Warren St., for May 2002 per BOE request.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000394433
Formal report of IAQ measurements collected at P.S. 89M in April 2002.
Similar indexed content
NYC-WTC_000392649
IAQ report for April 18, 2002 at PS 89M; BOE requested evaluation.
Similar indexed content
NYC-WTC_000369326
IAQ measurements collected June 20, 2002 for PS 89M.
Similar indexed content
NYC-WTC_000370089
ATC IAQ measurements conducted June 20, 2002 at PS 89M for BOE.
Similar indexed content
NYC-WTC_000313646
ATC IAQ measurements at PS 89M for May 13-14, 2002.
Similar indexed content