Air sampling for silica dust at a NYC school conducted February 2002; report dated March 18, 2002.

NYC-WTC_000312839
Page image
Scanned page image, NYC-WTC_000312839
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St New York, New York 10010 www.atc- en viro .com 212.353,8280 Fax 212.353.8306 ASSOCIATES INC.

March 18, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Silica Dust Stnyvesant High School ATC Project No. 15-19125-0246

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this report of air sampling for silica-containing dust conducted on February 27, 2002, at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of H. A. Bader, a consultant to the parents association.

ATC collected a total of twelve (12) samples for respirable dust using pre-weighed 37mm PVC filters connected to size-selective cyclones to remove the larger (non-respirable) particles prior to deposition on the filters. Eleven (11) samples were collected inside the building and one sample was collected outdoors. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association accredited laboratory in Reading, PA. One blank filter was also submitted. Analysis was performed by x-ray diffraction according to NIOSH Method 7500. A copy of the analytical report is attached.

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists from ATC’s New York City office, conducted the sampling. Sampling was conducted consistent with accepted industrial hygiene practices. The results represent the conditions on the day the samples were collected.

Silica was not found above the limits of detection in any of the twelve samples.

ATC appreciates the opportunity to provide this indoor air quality consultative service to the BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.

Sincerely, ATC Associates, In

James R. Cohn, CIH, CS: Regional Manager, Industrial Hygiene Division

Attachment

CITY_21MC100_003046987

NYC-WTC_000312839

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000312839Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000238357

Formal letter reporting results of respirable dust sampling conducted at Stuyvesant High School in late February 2002.

Similar indexed content

Compare copies and versions →