104 East 25th St., 10th Floor New York. New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 associates INC.

April 3, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Silica Dust Stuyvesant High School ATC Project No. 15-19125-0246

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this report of air sampling for silica-containing dust conducted on March 6 and 13, 2002, at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of H. A. Bader, a consultant to the parents association.

ATC collected a total of twelve (12) samples on each day for respirable dust using pre-weighed 37mm PVC filters connected to size-selective cyclones to remove the larger (non-respirable) particles prior to deposition on the filters. Eleven (11) samples were collected inside the building and one sample was collected outdoors. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association accredited laboratory in Reading, PA. One blank filter was also submitted. Analysis was performed by x-ray diffraction according to NIOSH Method 7500. A copy of the analytical laboratory report is attached.

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists from ATC’s New York City office, conducted the sampling consistent with accepted industrial hygiene practices. The results represent the conditions on the days the samples were collected.

Silica was not found above the limits of detection in any of the samples from either day.

ATC appreciates the opportunity to provide this indoor air quality consultative service to the BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.

Sincerely, ATC Associates,

James R. Cohn, CIH, CSP Regional Manager, Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_21MC100_003429726 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000175072

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000175072Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Silica dust air sampling report, June 2002

NYC-WTC_000175784

Report detailing respirable silica dust air sampling conducted at a school in April and May 2002 upon request from the Board of Education.

Similar indexed content

Compare copies and versions →