Pacs Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
Analytical Method 8290 Analysis Results
Tel: 612-607-1700
Client - ATC ASSOCIATES
Client's Sample ID ATC-0504-M833-DX2
Lab Sample ID 103517264
Filename F20513B_12
Injected By MRO
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 05/04/2002
ICAL Date 05/04/2002 Received 05/07/2002
CCal Filename(s) F20513A_14 & F20514A_01 Extracted 05/10/2002
Method Blank ID BLANK-1616 Analyzed 05/14/2002 04:46
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND — 0.0027 A 2,3,7,8-TCDF-13C 2.00 78
Total TCDF ND -- 0.0020 2,3.7,8-TCDD-13C 2.00 76
1.2,3,7,8-PeCDF-13C 2.00 70
2,3,7.8-TCDD ND 0.0035 A 2,3,4,7,8-PeCDF-13C 2.00 71
Total TCDD 0.017 0.0020 1.2,3,7,8-PeCDD-13C 2.00 70
1.2,3,4,7,8-HxCDF-13C 2.00 106
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 105
2,3,4.7.8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 99
Total PeCDF ND 0.0100 1,2.3,7,8,9-HxCDF-13C 2.00 88
1,2,3,4.7,8-HxCDD-13C 2.00 93
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6.7,8-HxCDD-13C 2.00 100
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 90
1,2.3,4,7,8,9-HpCDF-13C 2.00 70
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 79
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 65
2,3,4.6,7.8-HxCDF ND 0.0100
1,2,3,7.8,9-HxCDF ND 0.0100 1,2.3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7.8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 75
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2,3.4,6.7,8-HpCDF ND 0.0100 Total 2.3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.000036 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3.4,6,7,8-HpCDD ND 0.0100
Total HpCDD ND 0.0100
OCDF ND 0.0200
OCDD 0.036 0.0200 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted Isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1057194
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC1OO_OO3O29287
NYC-WTC_000310987