NYC 9/11 Public Portal Document
Pace Analytical Services, Inc
1700 Elm Street-Suite 20C
Minneapolis, MN 55414
^ace Analytical_________ Method 8290 Analysis Results
Tel: 612-607-170C
Client - ATC ASSOCIATES
Client s Sample ID ATC-0504-M833-DX3
Lab Sample ID 103517272
Filename F20518A_09
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 05/04/2002
ICAL Date 05/04/2002 Received 05/07/2002
CCal Filename(s) F20518A_01 & F20518A_17 Extracted 05/10/2002
Method Blank ID BLANK-1616 Analyzed 05/18/2002 22:42
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.0020 2,3,7,8-TCDF-13C 2.00 82
Total TCDF ND 0.0020 2,3,7,8-TCDD-13C 2.00 77
1,2,3,7.8-PeCDF-13C 2.00 75
2,3,7,8-TCDD ND 0.0028 A 2,3,4,7,8-PeCDF-13C 2.00 76
Total TCDD 0.016 0.0020 1.2,3.7,8-PeCDD-13C 2.00 76
1,2.3.4.7,8-HxCDF-13C 2.00 110
1,2,3.7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 93
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 98
Total PeCDF ND 0.0100 1,2,3,7,8.9-HxCDF-13C 2.00 82
1,2,3,4,7,8-HxCDD-13C 2.00 100
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 98
Total PeCDD ND 0.0100 1.2,3.4,6.7,8-HpCDF-13C 2.00 87
1.2.3,4,7,8,9-HpCDF-13C 2.00 71
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4.6,7,8-HpCDD-13C 2.00 60
1,2,3,6.7,8-HxCDF ND 0.0100 OCDD-13C 4.00 52
2,3,4,6.7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1.2.3.7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 76
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8.9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2.3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7.8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.000035 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.0100
Total HpCDD ND 0.0100
OCDF ND 0.0200
OCDD 0.035 0.0200 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substitutod isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration delected is below the calibration range NO = Not Detected
B = Less than 10 times higher than method blank level
NA = Not Applicable
P = Recovery outside ot target range
NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1057194
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003029288
NYC-WTC_000310988
OCR can misread numbers and units. Confirm readings against the page image before using them.