Pace Analytical Services, Inc
/^^ceAnalytical 1700 Elm Street-Suite 20C
Minneapolis, MN 55414
Tel; 612-607-170C
Method 8290 Analysis Results
Client - ATC ASSOCIATES
Client's Sample ID ATC-0504-M833-DX1
Lab Sample ID 103517256
Filename F20513B_11
Injected By MRO
Total Amount Extracted 1 ni2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 05/04/2002
ICAL Date 05/04/2002 Received 05/07/2002
CCal Filename(s) F20513A_14 & F20514A_01 Extracted 05/10/2002
Method Blank ID BLANK-1616 Analyzed 05/14/2002 03:57
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2.3,7,8-TCDF ND — 0.0031 A 2,3,7,8-TCDF-13C 2.00 76
Total TCDF 0.0057 — 0.0020 J 2,3.7,8-TCDD-13C 2.00 74
1.2,3,7.8-PeCDF-13C 2.00 72
2,3.7.8-TCDD ND 0.0036 A 2,3,4,7,8-PeCDF-13C 2.00 73
Total TCDD 0.0210 0.0020 1,2,3,7,8-PgCDD-13C 2.00 71
1,2,3,4,7,8-HxCDF-13C 2.00 100
1.2,3,7,8-PeCDF ND 0.0100 1.2,3,6.7,8-HxCDF-13C 2.00 101
2.3.4.7,8-PeCDF ND 0.0100 2,3.4,6,7.8-HxCDF-13C 2.00 95
Total PeCDF ND 0.0100 1,2.3.7,8,9-HxCDF-13C 2.00 90
1,2,3,4,7,8-HxCDD-13C 2.00 97
1,2,3,7,8-PeCDD ND 0.0100 1,2,3.6,7,8-HXCDD-13C 2.00 94
Total PeCDD 0.0100 0.0100 J 1,2.3,4,6.7,8-HpCDF-13C 2.00 97
1,2,3.4,7,8,9-HpCDF-13C 2.00 87
1,2,3,4,7,8-HxCDF ND 0.0100 1,2.3.4,6,7,8-HpCDD-13C 2.00 92
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 95
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1.2,3,7,8,9-HxCDD-13C 2.00 NA
1,2.3,4.7,8-HxCDD ND 0.0100 2,3.7,8-TCDD-37CI4 0.20 77
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8.9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1.2,3,4,6,7.8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8.9-HpCDF ND 0.0100 Equivalence: 0.000041 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6.7,8-HpCDD ND 0.0100
Total HpCDD 0.0100 0.0100 J
OCDF ND 0.0200
OCDD 0.0410 0.0200 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement
S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outsido of target range
NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1057194
REPORT OF LABORATORY ANALYSIS
This report shall not bo reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003029286
NYC-WTC_000310986