Spike sample, ATC/WIPE, 04/2002

Machine-extracted title · confidence 39%

Spike sample data processed with Method 8290 for WIPE matrix, dated 04/15/2002.

NYC-WTC_000309031–000309032
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street-Suite 200 Minneapolis, MN 55414

"^ace Analytical Method ____________ Laboratory Control Results 8290 Spike Tel: 612-607-1700 Fax: 612- 607-6444

Client - ATC

Lab Sample ID SPIKE-15B4 Filename F20423A_04 Matrix WIPE Total Amount Extracted 1 m2 Dilution NA ICAL Date 04/12/2002 Extracted 04/15/2002 CCal Filename(s) F20423A_03 & F20423A_16 Analyzed 04/23/2002 16:08 Method Blank ID BLANK-1572 Injected By MRO

Native Qs Qm % Internal ng's Percent Isomers (ng) (ng) Rec. Standards Added Recovery 2,3,7,8-TCDF 0.20 0.18 92 2,3,7,8-TCDF-13C 2.00 74 2,3,7,8-TCDD-13C 2.00 71 1,2,3,7,8-PeCDF-13C 2.00 71 2,3,7.8-TCDD 0.20 0.18 92 2,3,4,7.8-PeCDF-13C 2.00 75 1,2,3,7.8-PeCDD-13C 2.00 73 1,2,3,4,7,8-HxCDF-13C 2.00 109 1,2,3,7.8-PeCDF 1.00 0.94 94 1,2,3,6,7,8-HxCDF-13C 2.00 70 2,3,4,7,8-PeCDF 1.00 0.94 94 2.3.4,6,7,8-HxCDF-13C 2.00 91 1,2.3,7,8,9-HxCDF-13C 2.00 82 1,2,3,4,7,8-HxCDD-13G . 2.00 99 1,2,3,7,8-PeCDD 1.00 0.96 96 1,2.3,6,7,8-HxCDD-13C 2.00 86 1,2,3,4,6.7,8-HpCDF-13C 2.00 77 1,2,3,4,7,8,9-HpCDF-13C 2.00 74 1.2,3,4,7,8-HxCDF 1.00 0.91 91 1,2,3,4.6,7,8-HpCDD-13C 2.00 64 1.2,3,6,7,8-HxCDF 1.00 0.92 92 OCDD-13C 4.00 58 2,3,4,6,7,8-HxCDF 1.00 0.94 94 i.. j 1,2,3,7,8,9-HxCDF 1.00 0.94 94 1,2,3,4-TCDD-13C 2.00 NA 1,2,3,7,8,9-HxCDD-13C 2.00 NA

1,2.3,4,7.8-HxCDD , 1.00 0.96 96 2,3,7,8-TCDD-37CI4 0.20 72 1,2.3,6,7,8-HxCDD 1.00 0.97 97 1,2,3,7,8.9-HxCDD 1.00 0.93 93

1,2,3,4,6,7,8-HpCDF 1.00 0.95 95 1.2,3,4,7,8,9-HpCDF 1.00 0.97 97

J 1,2,3,4,6,7,8-HpCDD 1.00 0.94 94

OCDF 2.00 2.00 100 OCDD 2.00 1.91 95

Qs = Quantity Spiked Qm = Quantity Measured Rec. = Recovery (Expressed as Percent) P = Recovery outside of target range X = Background subtracted value Nn = Value obtained from additional analysis NA = Not Applicable ’ = See Discussion Report NO.....02-1055818

REPORT OF LABORATORY ANALYSIS ■! This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CITY_21MC100_003057497

NYC-WTC_000309031

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000309031Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Lab results, ATC spike, 2002

NYC-WTC_000370356

Spike-1578 with 04/12/2002 extraction and 04/17/2002 analysis for WIPE matrix.

Similar indexed content

Compare copies and versions →