NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ace Analytical ____________
Method 8290 Laboratory Control Spike Results
Tel: 612-B07-1700
Fax: 612- 607-6444
Client - ATC
Lab Sample ID SPIKE-DUP-1382
Filename F20423A_05 Matrix WIPE
Total Amount Extracted 1 m2 Dilution NA
ICAL Date 04/12/2002 Extracted 04/15/2002
CCal Filename(s) F20423A_03 & F20423A_16 Analyzed 04/23/2002 16:56
1 Method Blank ID BLANK-1572 Injected By MRO
Native Qs Qm % Internal ng's Percent
Isomers (ng) (ng) Rec. Standards Added Recovery
2,3,7,8-TCDF 0.20 0.19 94 2,3,7,8-TCDF-13C 2.00 69
2,3,7,8-TCDD-13C 2.00 68
1,2,3,7,8-PeCDF-13C 2.00 70
2,3,7,8-TCDD 0.20 0.19 95 2,3,4,7,8-PeCDF-13C 2.00 70
1,2,3,7,8-PeCDD-13C 2.00 70
1,2,3,4.7,8-HXCDF-13C 2.00 98
1,2,3,7,8-PeCDF 1.00 0.98 98 1,2,3,6,7,8-HxCDF-13C 2.00 66
2,3,4,7,8-PeCDF 1.00 0.99 99 2,3,4,6,7,8-HxCDF-13C 2.00 81
1,2,3,7,8,9-HxCDF-13C 2.00 72
1,2,3,4,7,8-HxCDD-13C 2.00 100
1,2.3,7,8-PeCDD 1.00 1.02 102 1,2,3,6,7,8-HxCDD-13C 2.00 77
1,2,3,4,6,7,8-HpCDF-13C 2.00 76
1,2,3.4,7,8,9-HpCDF-13C 2.00 81
1,2,3,4,7,8-HxCDF 1.00 0.98 98 1,2,3,4,6,7,8-HpCDD-13C 2.00 68
1,2,3,6,7.8-HxCDF 1.00 0.98 98 OCDD-13C 4.00 72
2,3,4,6,7,8-HxCDF 1.00 0.99 99
1.2,3.7.8,9-HxCDF 1.00 0.99 99 1,2,3,4-TCDD-13C 2.00 NA
1,2,3,7,8,9-HxCDD-13C 2.00 NA
1.2,3,4,7,8-HxCDD 1.00 1.00 100 2,3,7,8-TCDD-37CI4 0.20 74
1,2,3,6.7,8-HxCDD 1.00 1.02 102
1,2,3.7,8,9-HxCDD 1.00 0.94 94
1,2,3.4.6,7,8-HpCDF 1.00 1.01 101
1.2.3,4,7,8,9-HpCDF 1.00 1.01 101
1.2,3,4,6,7,8-HpCDD 1.00 1.02 102
J OCDF
OCDD
2.00
2.00
2.16
2.06
108
103
Qs = Quantity Spiked
Qm = Quantity Measured
Rec. = Recovery (Expressed as Percent)
P = Recovery outside of target range
X = Background subtracted value
Nn = Value obtained from additional analysis
NA = Not Applicable
’ = See Discussion Report No.... 02-1055817
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_002871499
NYC-WTC_000375788