March 1, 2002
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Metals
P.S. 234M
ATC Project No. 15-19125-0279
Dear Mr. Orlan:
ATC Associates, Inc. (ATC) is pleased to provide this report of air sampling for metals in
airborne dust on February 19, 2002, at the referenced school. The New York City Board of
Education (BOE) requested this sampling at the recommendation of Environ Corp., the consultant
retained by the parents association.
Scope of Work
ATC collected four (4) samples for metals at specified locations. Samples were collected for a
minimum of" eight (8) hours using 37 mm mixed cellulose ester filters connected to battery-
powered sampling pumps at a flow rate of 2 liters per minute. Pumps were calibrated before and
after each sampling period. Two (2) samples were collected inside the building and two (2) were
collected outdoors. One blank sample was also submitted. The samples were sent to PSC
Analytical Services, Inc., an American Industrial Hygiene Association-accredited laboratory in
Reading, PA. Analysis was performed by NIOSH Methods 7300M. Each sample was analyzed
for a panel of eleven (11) metals. The metals were aluminum (Al), cadmium (Cd), chromium
(Cr), cobalt (Co), copper (Cu), iron (Fe), magnesium (Mg), manganese (Mn), molybdenum (Mo),
nickel (Ni) and zinc (Zn). A copy of the analytical report is attached.
The sampling locations were the Mam Entrance Lobby, floor Hallway, the west Playground
and the Roof.
Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists from ATC’s New York City
office, conducted the sampling.
The established regulatory values for metals are intended for industrial workplace exposures and
are not generally applicable to office/school settings. There are no standards for these metals in
indoor air in non-industrial situations. The Environmental Protection Agency (EPA) has set a
screening level for hexavalent chromium (the more toxic form) in air of 0.6 ug/m\ this assumes a
continuous exposure for one year. These samples were analyzed for total chromium (trivalent
and hexavalent). The results represent conditions at the time the samples were collected.