NYC 9/11 Public Portal Document
o,9 9000 *^9:2^ ^.96
5fcH-28-2001 FRJ 12:45 PH NIOSH/R-Il FAX NO. 5134587147 P. 03
Centers for Disease Control and Prevention
National Institute for Occupational Safety and Health
(nlerim Air Sampling Report
Thureday, September 20, 2001
Investigators from the National Institute for Occupational Safety and Health (NIOSH) collected
air samples in areas immediately adjacent to the d^ris pile and on personnel actively involved in
rescue efforts in the vicinity of die debris pile to characterize potential exposures. Below are the
interim sampling results for Thursday, September 20,2001.
Air Samples
AihesMs
• 54 personal and 5 area air samples were collected by NYDOH contractors
o Most personal sample 8-hour time-weighted average concentrations were below
0,025 fibers/cc as detemjined by PCM (two were 0.08 fibers/cc)
o All area sample results were below 0.008 fibers/cc as determined by PCM
Total Dust
• 3 personal air samples were collected for total dust
o Personal sample 8-hour time-weighted average concentrations were below 1.0
mg/m^
Respirable
• 6 personal air samples were collected for respirable dust
o Personal sample 8-hour time-weighted average concentrations were below 0.05
mg/m’
Acetals
• 5 area air samples were collected for metals
o Nothing of concern was found regarding metal analysis
Ct-ysiailine silica
• 4 personal air samples were collected for crystalline silica
o No crystalline silica was detected on any of the air samples
yolatJ/c Organic Ct»tipoundi- (VOCsJ
• I air sample was collected on a thermal desorption tube (used as a screening technique)
o Compounds identified included benzene, toluene, and polynuclear aromatic
hydrocarbons which have been attributed to products of combustion
Q Concentrations of VOCs were well below established limits
• 9 ah samples ware collected with charcoal adsorbent tubes
o Concentrations of VOCs on all samples were below detectable limits
SSP. ae 'Cl (FBI) 19-41 COMMUNICATION N»;52 PACK. 3