NYC 9/11 Public Portal Document o«"3 2 2200 00‘^-0^ Pex: 5C.-dtt-2UUl HKI 12:45 PH MIOSH/R-ll FAX NC. 5134587147 P. 04

Centers for Disease Control and Prevention National Institute for Occupational Safety and Health Interim Air Sampling Report Friday, September 21,2001

Investigators from the National Institute for Occupational Safety and Health (NiOSH) collected air samples in areas immediately adjacent to the d^ris pile and on personnel activeiy involved in rescue efforts in the vicinity of the debris pile to characterize potential exposures. Below are the toterim sampling results for Friday, September 31,3001.

Air Samples

Jshesfos • 45 personal and 6 area air samples were collected by NYDOH contractors o Personal sample 8-hour time-weighted average concentrations were below 0.04 fibers/cc as determined by PCM o All area sample results were below 0.01 fibers/cc as detennined by PCM

jlofalDifSt • 15 personal air samples were collected for total dust o Personal sample 8-hour time-weighted average concentrations were below 1.0 mg/m’

Meials • 7 personal and 4 area air samples were collected for metals o Nothing of concern was found regarding metal analysis

C/ystaiUne s/i/ca • 2 personal air samples were collected for crystalline silica o No crystalline silica was detected on any of the air samples Carbon Monoxide • 5 real-time personal breathing zone samples were collected for carbon monoxide o Most 8-hour time-weighted average concentrations were below 2 ppm (one was 32 ppm) o A single peak of 823 ppm was observed on a torch cutter

SSP. 23 01 (FRI> communication No .-52 PA&E4

CITY_21MC100_008979993

NYC-WTC_OOO3O8192

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000308192Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000289950

NIOSH/NYS DOH interim air sampling results near debris pile; asbestos and total dust data.

Similar indexed content

Compare copies and versions →