NYC 9/11 Public Portal Document
O''7 2 200C 20:25 ^.05
■
^ir-c;o-^UUl rKI 12:44 FH HIOSK/R-Il FAX NO 5134587147 P. 02
Centers for Disease Control and Prevention
National Institute for Occupational Safety and Health
Interim Bulk and Air Sampling Report
Wednesday, September 19, 2001
Investigators from the National Institute for Occupational Satiety and Health (NIOSH) collected bulk and air
samples in areas ittunediately adjacent to the debris pile and on personnel actively involved in rescue efforts in
the vicinity of the dd>ris pile to characterize potential exposures. Below are the interim sampling results for
Wednesday, September 19,2001.
Bulk Samples
Asbestw
• 27 bulk samples were collected from undisturbed loose material within the restricted area
o Most samples indicated less than 1% asbestos (two contained between 1 and 3% asbestos)
Crysiallme Silica
• 21 bulk samples were collected from undisturbed loose material within the restricted area
o All samples contained quartz, typically in amounts less than 5%, although one sample was as
high as 18% quartz
o None of the samples contained cristobalite
Metals
• 27 bulk samples were collected from undisturbed loose material within the restricted area
o Noting of concent was found regarding metal analysis
Air Samples
Asbestos
• 3 personal samples and 3 area air samples were collected by NTOSH investigators
o All task'-ba^ed concentrations were below 0.05 fibers/cc as determined by TEM analysis
• Additional air samples were collected by NYDOH contractors (26 personal and 4 area)
o Personal sample 8-hour time-weighted average concentrations were below 0.05 fibers/cc as
determined by PCM
o 3 personal samples were analyzed by TEM; all were less than 0,004 fibers/cc
o Area sample results were below 0.04 fibers/cc as determined by PCM
Trj/eilI>USI
• 17 air samples were collected for total dust personal and 10 area)
o Personal sample 8-hour time-weighti average concentrations were below 1.0 mg/m’
o Area sample concentrations were below 1.7 mg/m’
Metals
• 17 ail samples were collected for metals (7 personal and 10 area)
o Nothing of concern was found regarding metal analysis
Carban Monoxide
• 5 real-time personal breathing zone samples were collected for carbon monoxide
o All 8-hour time-waghted average concentrations were below 3 ppm
o A single peak of 79 ppm was observed on a city transit worker
k'oiatile Organic Ci»n/>aunds 0''OCs}
« 6 air samples were collected on thermal desorption tubes (used as a screening technique)
o Compounds identified included benzene, toluene, and polynuclear aromatic hydrocarbons which
have been attributed to products of combustion
o Concentrations of VOCs on all samplos were well below established limits
• 19 air .samples were collected with charcoal adsorbent tubes
o Concentrations of VOCs on all samples were below detectable limits
arzp. 28 01 (raj) iS'4i eoMMUXication No-sa pags. 2
CITY_21MC100_008979991
NYC-WTC_000308190
OCR can misread numbers and units. Confirm readings against the page image before using them.