NYC-WTC_000287898
Preliminary data report for World Trade Center sampling at PATH dewatering location.
18 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗PATH dewatering sample results; toxicity and BOD summary for WTC tunnel-related testing.
NYC-WTC_000307523–000307528OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
was no residual chlorine present. Dissolved oxygen, determined in the laboratory, was 2.5 mg/L, lower than saturation indicating an oxygen demand from the sample. The alkalinity of the sample was approximately 140 mg/L. This concentration is slightly higher than would be predicted for a sample with a balanced salinity of 12 ppth.
Metals: Several metals were detected that had not been detected in the Hudson River samples or the 10/03/01 PATH Exchange Place sample. Results for these metals is tabulated below. Results for zinc exceed both the marine acute and chronic Federal Water Quality Criteria for this metal. Chromium and nickel were detected at concentrations slightly greater than the detection limit. Concentrations of other metals detected in the sample are similar to those detected in the 10/03/01 PATH tunnel discharge sample. Table 1 at the end of this report provides metals data for all non-drinking water WTC disaster samples collected by EPA.
Metal Concentration Marine Acute Marine Chronic (ug/1) FWQC (ug/1) FWQC (ug/1) Chromium 8.4 1100* 50* Nickel 6.8 75 8.3 Zinc 210 95 86 * FWQC for Chromium VI, most stringent chromium criteria.
PCB Congeners: The sample was analyzed for 71 PCB congeners. No PCBs were detected in the sample (DL 0.0054 ug/L).
NVOAs: Seven (7) non-PAH NVOAs were detected in the sample. Seven PAHs, most substituted napthalenes, were also detected, but all at trace concentrations (< lOug/L). Results are tabulated below. Benzoic acid was detected at the highest concentration (580 ug/L), followed by phenol and several substituted phenols. Phenol is the only detected NVOA having established marine acute FWQC. Marine chronic criteria has not been established for phenol. The concentration detected in the PATH tunnel effluent is more than 10 times less than the marine acute FWQC. Proposed acute and chronic FWQC for 2,4,5-trichlorophenol were also not exceeded in the sample.
Compound Concentration Marine Acute Marine Chronic (ug/1) FWQC (ug/1) FWQC (ug/1) Benzoic Acid 580 NA NA Phenol 450 5,800 NA 4-Methyl Phenol no NA NA
CITY_21MC100_003038874
NYC-WTC_000307525
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000287898
Preliminary data report for World Trade Center sampling at PATH dewatering location.
18 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307428
Preliminary results for dioxins, furans, asbestos, and BOD at WTC dewatering sample.
18 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000204859
Preliminary data summary report on dioxins, furans, asbestos, and biochemical oxygen demand from PATH dewatering samples collected in October 2001.
17 shared non-person entities · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432195
Final preliminary data from NYC World Trade Center sampling; VOCs, PCBs, PAHs, metals, etc.
11 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432102
Final preliminary data for World Trade Center sampling; DOS project summary.
11 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241840
Preliminary bulk and VOC sampling data near WTC debris and Hudson River discharge.
11 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304415
Preliminary results for VOCs, PCBs, PAHs, metals and asbestos from PATH-related sampling.
11 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340934
Preliminary results for dewatering samples around PATH location, VOCs and PAHs detected.
17 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302159
Preliminary data for WTC area sampling across VOCs, PCBs, PAHs, metals, and asbestos; PATH tunnel permit noted.
11 shared non-person entities · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340929
Preliminary data on VOCs, PCBs, PAHs and hazardous substances from WTC sampling.
13 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432199
Preliminary dewatering discharge sampling results; various contaminants and comparatives.
15 shared non-person entities · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432150
Preliminary NYCWTC sampling data with VOCs, PAHs, and other metrics, Oct 2001.
15 shared non-person entities · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000287898
Preliminary data report for World Trade Center sampling at PATH dewatering location.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307428
Preliminary results for dioxins, furans, asbestos, and BOD at WTC dewatering sample.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000204859
Preliminary data summary report on dioxins, furans, asbestos, and biochemical oxygen demand from PATH dewatering samples collected in October 2001.
Similarity score 0.964 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250995
Final preliminary data for NYC/World Trade Center sampling from PATH area and Hudson River discharge.
Similarity score 0.961 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340934
Preliminary results for dewatering samples around PATH location, VOCs and PAHs detected.
Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432150
Preliminary NYCWTC sampling data with VOCs, PAHs, and other metrics, Oct 2001.
Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000287898
Preliminary data report for World Trade Center sampling at PATH dewatering location.
Similar indexed content
NYC-WTC_000307428
Preliminary results for dioxins, furans, asbestos, and BOD at WTC dewatering sample.
Similar indexed content
NYC-WTC_000204859
Preliminary data summary report on dioxins, furans, asbestos, and biochemical oxygen demand from PATH dewatering samples collected in October 2001.
Similar indexed content
NYC-WTC_000432195
Final preliminary data from NYC World Trade Center sampling; VOCs, PCBs, PAHs, metals, etc.
Similar indexed content
NYC-WTC_000432102
Final preliminary data for World Trade Center sampling; DOS project summary.
Similar indexed content