NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 6 pages

New York City/ World Trade Center sampling report

Machine-extracted title · confidence 40%

PATH dewatering sample results; toxicity and BOD summary for WTC tunnel-related testing.

NYC-WTC_000307523–000307528
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NVOAs (Region 2) Metals + mercury (Region 2) BODS (Region 2) COD (Region 2) Aquatic Toxicity (marine Mysids and Minnows) (Region 2) TSS (Region 2) Total Petroleum Hydrocarbons (Region 2) Oil and Grease (Region 2) Sulfate (Region 2) Chloride (Region 2) Salinity (Region 2) Dissolved Oxygen (Region 2) Residual Chlorine (Region 2) Alkalinity (Region 2) Ammonia (Region 2) Dioxins/Furans (contract lab - Paradigm Analytical) Asbestos (contract lab)

Dewatering Activity: The Port Authority of New York and New Jersey (PANYNJ) initiated pumping from the PATH tunnels at Exchange Place under an existing permit (NJ0076988) on September 11,2001. PANYNJ estimates that discharge averages 2600 GPM. The F tuimel has been plugged since the WTC disaster, and no dewatering is occurring from that tunnel. Dewatering continues from the E tunnel. Pumps are activated by a manual “float switch”, and operate between 8 and 12 hours per day. The tunnel is estimated to fill at between 800 - 1200 gpm. NJDEP had been notified of the enhanced discharge, but neither performed sampling or required additional sampling by PANYNJ. EPA learned of the enhanced discharge on October 01, 2001, performed reconnaissance on October 02, and sampled the discharge on October 03. There were no significant contaminant concentrations detected in that sample.

Plugging the PATH tunnel F near Exchange Place will necessitate pumping the tunnel from Manhattan. The plug is expected to be in place by 10/10/01. PANYNJ has suggested that they would prefer to discharge directly to the Hudson River. There does not appear to be an existing NPDES permit for the proposed discharge. EPA was informed on 10/09/01 that the characteristics of the discharge at Exchange Place had changed, and was now “black and smelly”. To address this, and to characterize the discharge more fully to assess the expected quality of the proposed discharge from the Manhattan side, EPA re-sampled the discharge at Exchange Place on 10/10/01.

Preliminary Results:

General Characteristics: The samples were brown in color with a strong acrid odor. Some, but not all of the color, was removed through centrifugation. Total ammonia was elevated with a concentration of approximately 8.7 mg/L. Ammonia is not typically encountered at this concentration in marine surface samples. Salinity in the sample was 12 parts per thousand (ppth, g/L) which is less than the average of 35 g/L salinity of seawater. There

CITY_21MC100_003038873

NYC-WTC_000307524

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000307524Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →