Final preliminary data, NYC World Trade Center sampling

Machine-extracted title · confidence 48%

Preliminary results for dioxins, furans, asbestos, and BOD at WTC dewatering sample.

NYC-WTC_000307428–000307437
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

on 10/10/01.

Preliminary Results:

General Characteristics: The samples were brown in color with a strong acrid odor. Some, but not all of the color, was removed through centrifugation. Total ammonia was elevated with a concentration of approximately 8.7 mg/L. Ammonia is not typically encountered at this concentration in marine surface samples. Salinity in the sample was 12 parts per thousand (path., g/L) which is less than the average of 35 g/L salinity of seawater. There was no residual chlorine present. Dissolved oxygen, determined in the laboratory, was 2.5 mg/L, lower than saturation indicating an oxygen demand from the sample. The alkalinity of the sample was approximately 140 mg/L. This concentration is slightly higher than would be predicted for a sample with a balanced salinity of 12 path.

Dioxins/Furans: One dioxin and one furan were detected. OCD was reported at a concentration of 53.2 J pg/L, and 1234678-HpCDF was reported at a concentration of 9.2 pg/L. The Toxic Equivalency (TEQ) for the compounds detected in the sample is 0.1 pg/L. This value is less than median TEQs determined over the last three years by NYSDEC in samples collected during NYNJ Harbor Estuary Contaminant Assessment and Reduction Program (CARP). The median TEQ (n=16) for the eastern NYNJ Harbor is 0.13 pg/L; the TEQ (n = 20) for the western NYNJ Harbor is 1.3 pg/L.

Metals: Several metals were detected that had not been detected in the Hudson River samples or the 10/03/01 PATH Exchange Place sample. Results for these metals is tabulated below. Results for zinc exceed both the marine acute and chronic Federal Water Quality Criteria for this metal. Chromium and nickel were detected at concentrations slightly greater than the detection limit. Concentrations of other metals detected in the sample are similar to those detected in the 10/03/01 PATH tunnel discharge sample. Table 1 at the end of this report provides metals data for all non-drinking water WTC disaster samples collected by EPA.

Metal Concentration Marine Acute Marine Chronic (ug/1) FWQC (ug/1) FWQC (ug/1) Chromium 8.4 1100* 50* Nickel 6.8 75 8.3 Zinc 210 95 86 * FWQC for Chromium VI, most stringent chromium criteria.

PCB Congeners: The sample was analyzed for 71 PCB congeners. No PCBs were detected in the sample (DL 0.0054 ug/L).

NVOAs: Seven (7) non-PAH NVOAs were detected in the sample. Seven PAHs, most

CITY_21MC100_006733583

NYC-WTC_000307430

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000307430Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →