WKP BSOil LABORATORIES, INC AIR SAMPLE ANALYSIS REPORT PHASE CONTRAST MICROSCOPY

CLIENT; WARREN & PANZER ENGINEERS. P.C turnabouno Tims 24HRS WKP FILE# 501-01 Sample DATE 4/20^02 WKPLOGI.D.# N02Q4227, N0204228. and NC204225 RECEiVEO DATE 406/2002 COrttra«#; WTCAR2 analysis DATE 4-29.2002

REPORT DATE 409/2302 CLIENT JOB: NYC Department of Environmentel Protection CLIENT JOB#; 1079.01.01 LOCATION S.W.Area/ Site Map ANALYSIS; AIRBORNE FIBER COUNTING, PHASE CONTRAST MICROSCOPY, NIOSH 7400. NIOSH PAT Lab NO. 07166; NY COLLECTION DEVICE 25 mm MCE Alter Cassette; Collection Area = 3S5 W mm;

SAMPLE WERE COLLECTED BY; Festy Ofiomwegie, West Erhabor, and E. Dibra

SUMMARY OF ANALYSIS CLIENT FIBERS/ FIBERS/ SAMPLE# Site# SAMPLE LOCATION Vol. St) mm cc

1079,01.01 001 27 Gateway Plaza Park Area 675 0.00 <0004 002 31 South End Ave. and Albany Street 875 0.00 <0.004 003 32 West Street and Albany Place 675 0.00 <0,004 004 33A Rector Place by the Park Place 675 0.00 <0,004 005 34 W. Thames Street - Along Waterfroril 675 0.00 <0.004 006 37 West of Third Place 675 0.00 <0004 007 e West Street and Warren Street 675 0.00 <0 004 QOS 4 River Terrace and Chamber Street 675 0.00 <0,004 009 6A River Terrace Park Area Between Park Place and Warren Street 675 1,90 <0004 010 9 River Terrace and Park Place West 675 0.00 <0004 011 17 River Terrace end Vesey 675 0.00 <0.004

012 7 Warrsn Street and North End Avenue 675 1.30 <0.004 013 10 North End Avenue Park place West 67S 0.00 <0.004 014 29 Trinity Place and Thames Street 575 0.00 <0.004 015 21 Fulton and Church Street 675 0.00 <0.004 016 20A Vesey Street and West Broadway 676 0.00 <0,004 017 16 Park place and Chureh Street 67S 0.00 <0.004 018 12 Murray Street and Church Street 675 0.00 <0.004 019 15 Park Place and Greenwich Street 675 0.00 <0.004 020 11 Murray Street and Greenwich Slreei 67S 0.00 <0.004 021 Field Blank 0.00 022 Field Blank 0,00

NOTES: 1.5.5 fibers/100 fields was used to calculate the limit of detection (LOD).Results below the LCD have no statistical validity. 2. Samples ware not collected by WKP Laboratories, Inc. 3, The Federal EPA Clearance Critical following an asbestos abatement project is o 010 fibers/cc, 4. PCM air samples will be disposed of after 3 months unless otherwise directed by client in writing.

Louis Lombardi

laboratory ANALYST laboratory director

CITY_21MC100_008978488

NYC-WTC_000307161

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000307161Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →