NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Air sample analysis report, Phase Contrast Microscopy

Machine-extracted title · confidence 83%

WKP Laboratories air analysis; Phase Contrast Microscopy; 24-hour turnaround; 2005.

NYC-WTC_000307124
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

WKP pass i! I 'f LABORATORIES. INC AIR SAMPLE ANALYSIS REPORT PHASE CONTRAST MICROSCOPY

CLIENT: WARREN & PANZER ENGINEERS, P C. TURhiAROUNDTIME 24MRS WKP FILE# 501-01 SAMPLE DATE »13«2 wkplogi.d.# NC205S3, N02058A, and NO20S&5 RECEIVED DATE Conirad #. WTCAR2 ANALYSIS OATB 5/14TO

REPORT date CLIENT JOB: NYC Department of Environmental Protection CLIENT JOB#; 1079.01.01 LOCATION S.W. Area/ Site Map ANALYSIS; AIRBORNE FIBER COUNTING. PHASE CONTRAST MICROSCOPY. NIOSH 7400. NIOSH PAT Lab NO. 07186; NY COLLECTION DEVICE; 26 mm MCE Filter Cassette; ColieWion Area ■ 385 sq mm;

SAMPLE WERE collected BY: Warren and Panzer

SUMMARY OF ANALYSIS CUENT FIBERS/ FIBERS/ SAMPLE# Site# SAMPLE LOCATION Vol. aq mm cc

1079.01.01 001 27 Gateway Plaza Park Area 675 1.30 <0.004 002 31 South End Ave. and Albany Street 675 5.10 <0,004 003 32 West Strear and Albany Place 675 2.50 <0.004 004 33A Rector Race by the Park Place 676 S.10 <0.004 005 34 W. Thames Street - Aong Waterfront 676 1.30 <0.004 006 37 West of Third Place 675 2.50 <0 004 007 £ West Street and Warren Street 673 3.80 <0-004 006 4 River Terrace and Chambers Street 675 8,90 - 0.005, 009 6A RNer Terrace Park Area Between Park Plate and Warren Street 873 6,40 <0.004 010 9 River Terrace and Park Place West 675 2.50 <0.004 011 17 River Terrace and Vesey 675 2.S0 <0.004 012 - Warren Street and North End Avenue 675 3.80 <0 004 013 10 North End Avenue Park place West 675 0.00 <0.004 014 29 Trinity Place and Thames Street 675 1.30 <0.004 016 21 Fulton and Church Street 675 1.90 <0.004 0 0C5 / 016 20A Vesey Street and West Broadway S7S 8.90 017 18 Park place and Church Street 675 7.60 _ 0,004 Y 018 -12 Murray Street arw Church Street 67S 12.70 _ 0.007 y Park Place and GreemMich Street 10.20 - 0.006-/ 019 - 15 675 Murray Street and Greenwich Street 6.40 - 0.004 V 020 .-n 675 021 Field Blank 0-00 022 Field Blank 0.00

NOTES: 1.5.5 fifcers/100 fields was used to calculate the limit of detection (LOO). 2. Samples were not collected by WKP Laboratones. Inc. 3. The Federal EPA Clearance Critical following an asbestos abatement project is 0.010 fibers/cc. ' 4. PCM air samples will be disposed of after 3 months unless otherwise directed by client in writing.

O,M.

laboratory analyst LABORATORY DIRECTOR

CITY_21MC100_008978433

NYC-WTC_000307124

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000307124Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000307121

Air sample analysis, Phase Contrast Microscopy for Warren & Panzer; 2 hours turnaround.

Similar indexed content

NYC-WTC_000348112

Airborne fiber counting with phase contrast microscopy for NYC DEP, 6/27/02.

Similar indexed content

Compare copies and versions →