WKP LABORATORIES, INC SI AIR SAMPLE ANALYSIS REPORT PHASE CONTRAST MICROSCOPY

CLIENT; WARREN & PANZER ENGINEERS, P.C. turnaround time 24HRS WKP FILE# 501-01 SAMPLE date 7«3«2 WKP LOG I.O. # N0207332, N0207333, AND N0207334 RECEIVEO DATE 7/iata ConUatt WTCAR2 ANALYSIS DATE Ta4Aa

REPORT DATE 7/2402 client JOB; NYC DepartmeiK of Environmcnial Protection CLIENT JOB #: 1079.01,01 location S.W. Are#/ Site Map ANALYSIS; AIRBORNE FIBER COUNTING. PHASE CONTRAST MICROSCOPY, NIOSH 7400. MOSH PAT Lab NO. 07106; NY COLLECTION DEVICE; 25 mm MCE Filter Cassette; Collection Area = 305 sq mm'

SAMPLE WERE collected BY: WatT«n and Panzer Engineers, P.C.

SUMMARY OF analysis CLIENT FIBERS/ FIBERS/ SAMPLE# Site# SAMPLE location vpl. sq mm cc

1079,01.01 001 27 Gateway Plaza Park Area 675 2.50 <0,004 002 31 South End Ave. and Albany Street 675 3 60 <0004 003 32 West Street and Albany Place 675 1.30 <0 004 004 33A Rector Place by the Park Place 67S 6.40 <0.004 005 34 W. Thames Street - Along Waterfront 675 1 30 <0.004 006 37 West of Third Place B7S 1.30 <0.004 007 8 West Street and Warren Street 675 8.90 0.005 008 4 River Terrace and Chambers Street 675 7.60 0.004 009 6A River Terrace Park Area Between Park Place and Warren Street 675 3.80 <0.004 010 9 River Terrace and Park Place West 675 1.30 <0.004 011 17 River Terrace and Vesey 675 12.70 0.007 012 7 Warren Street and North End Avenue 675 5.10 <0.004 013 10 North End Avenue Park place West 676 2.50 <0.004 014 29 Trinity P.iace and Thames Street 676 5.10 <0.004 015 21 Fulton and Church Street 675 7.60 0-004 016 20.4 Vesey Street and West Broadway 675 2.50 <0.004 017 16 Park place and Church Street 676 5.10 <0.004 016 12 Murray Street and Church Street 675 1.30 <0.004 019 15 Park Place and Greenwich Street 67S 5.10 <0.004 020 11 Murray Street and Greenwich Street 675 3.20 <0,004 021 Field Blank 0.00 022 Field Blank 0.00

NOTES: 1.5.5 Rbers/lOO fields was used to calculate the limit of detection (LOD). 2. Samples were not collected by WKP Laberalories, Inc. 3. The Federal EPA Clearance Critical following an asbestos abatement project is 0.010 ftbers/cc. 4. PCM air Semples will be disposed of ehor 3 months unless otherwise directed by client in writing

D.M. LASbRAt uRY"A^iXLti ti 1 lmIOHAtOWV UIWfCTUrt

CITY_21MC1OO_O11O9861O

NYC-WTC_000307167

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000307167Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348117

Air sample analysis for NYC DEP, 6/28/02, Warren & Panzer.

Similar indexed content

Compare copies and versions →