•25-2Ce2 -7'^ PVGI E'^^ET; Co NYC ? 2-^4 ers? p.03/2'.

Ms. Peggy Nash September 27,2001 Page 2

Sample Data and Discussion

Please refer to copies of the attached analytical laboratory’s report for the results of the sampling conducted. In summary, the levels of measured airborne fibers present during the sampling period were low, and did not approach or exceed any applicable, enforceable industrial exposure limits as set by govemmental agencies.

At the present time, there are no non-industrial indoor air quality standards, or permissible exposure limits for airborne asbestos. However, a generally accepted airborne fiber concentration for “Clean Air” subsequent to a.sbestos abatement activities in commercial buildings in New York City i.s 0.01 fibers per cubic centimeter (f/cc). This 0.01 f/cc concentration is also referred to as a “Reoccupancy Criteria” by the NYC Department of Environmental Protection.

Subsequent to the environmental cleaning, the airborne fiber concentration was found to be below this (0.01 t/cc) value on all floors at 170 Broadway.

With regards to sampling analysis, optical Phase Contra.st Microscopy (PCM) ns a standard analytical method to assess airborne fiber concentration. This method does not distinguish between asbestos and non-asbestos fiber types, and only those fibers wider than 0 25 micrometers, greater than 5 micrometers in length, and with a length-to-width (aspect) ratio equal to or greater than .3:1 were counted. Because of lhe.se limitations, fiber counts by PCM typically provide an “index" of the total concentration of particulates in the ambient air of an occupied building.

If you have any questions or coinmcnts regarding the information presented herein, please feel free to contact Hygienetic.s at (212) 244 - 3443.

Very truly yours,

Laurence M, Jareti/ Project Director

(attachinent)

2060.033

CITY_DEP_WORBY_CANNATA_SUBP_000007160

NYC-WTC_000306377

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000306377Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →