NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 24 pages

Lab report, NL height peaks, W010210B

Machine-extracted title · confidence 25%

Matched GC peaks and ratios for W010210B with QC checks, Jan 2002.

NYC-WTC_000304905–000304928
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Initial ..Date..

Data Review By: ' Channel specific noise levels computed from 'ML' heights.

•he Total Area for each peak with an ion abundance ratio outside ratio limits has been recalculated according to method requirements.

Page Ho. 1 Listing of W010210B.db{ 01/17/2002 Hatched GC Peaks / Ratio / Ret. Time

Compound/ OC-Log Omit Why ..RT. OK Ratio Total.Area/Hc Area/Ht.Peakl Area/Ht.Peak2 Rel.RT Compound.Name.. ID,, Flags.

TCDF 0.65-0.89 0.961-1.232 304-306 DC KL Height 15.22 9.41 5.91 23:16 0.72 438.84 184.16 254.68 0.698 2 3:32 0.75 899.06 385.67 513.39 0.908 24:00 0.70 1,756.09 724.42 1,031.67 0.926 24:13 0.6B 993.82 402.36 591.46 0.934 24:37 0.73 1,626.02 769.B3 1,056.19 0.950 24:54 0.77 1.569.04 6B2.24 BB6.e0 0.961 2 5:07 0.74 2,675.55 1,140.27 1,535.28 0.969 25:21 0.77 2,213.56 960.14 1,253.42 0.978 25:32 0.77 794.49 346.17 448.32 0.965 i278-TCDF AN 25:45 0.66 727.31 290.38 436.93 0.994 25:57 0.75 4.312.15 1,845.71 2,466.44 1.001 237e-TCDF AN 26:22 0.75 839.23 358.37 430.86 1.017 26:34 0.71 099.13 373.99 525.14 1 .025 X X 26:46 RO 0.79 433.18 191.30 241.80 1.033 27:01 RO 0.58 109.37 47.58 82.2B 1.042 27:40 RO 1.28 179.42 129.82 101.37 1.068 DC WH 27:57 0.70 130.64 1.078 304-306 16 Peaks 20,666.26

13C12-TCDF 0.65-0.89 0.961-1.039 316-318 DC ML Height 5.52 3.03 2.49 DC , WL 24:53 0.74 63.23 0.960 25:31 0.77 108.61 47.17 61.44 0.9B5 25:55 0.75 16.066.87 6,862.10 9,204.69 1.000 13C12-237B-TCDF ISO Height 4.363.99 1,778,76 2,385.23 26:17 0.09 90.26 ^2-52 47.74 1.0X4 26:27 ROI 1.33 25.17 18.97 14.22 X.021 DC SN 26:39 RO> 0.57 22.60 1.028 316-318 4 Peaks 16.290.91

Above; TCDF / TCDD Follows

TCDD 0.65-0.89 0.962-1.226 320-322 DC ML Height 7.26 3.85 3.41 24:07 0.76 4.714.91 2.030.60 2.684.31 0.906 136a-TCDD AH 24:29 0.77 5,045.55 2.196.46 2,849.09 0.919 1379-TCDD AH 24 :4B 0.65 1,079.96 424.89 655.07 0.931 DC SN 25:00 RO 1.10 22,69 0.939 25:27 0.76 2,158.08 934.51 1,223.57 0.956 25:43 0.81 1,377.41 615.08 762.33 0.966 26:08 0.77 638.79 276.90 361.89 0.9S1 M 26:33 0.79 2.470.00 1.090.00 1,380.00 0.997

Triangle Laboratories, Inc.® 801 Capitola Drive • Durham, North Carolina 27713 Printed: 14:51 01/17/2002 Phone: (919) 544-5729 • Fax: (919) 544-5491 389

CITY_21MC100_003114164

NYC-WTC_000304905

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000304905Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →