NYC-WTC_000278249
Laboratory report for PCDD/PCDF analysis (dioxin) from NYC WTC area samples, Jan 2002.
4 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Laboratory report for PCDD/PCDF analysis (dioxin) from NYC WTC area samples, Jan 2002.
NYC-WTC_000278231–000278248OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Initial .. . .Date. . .
Data Review fiy: Channel specific noise levels computed from ’ML' heights.
rhe Total Area for each peak with an ion abundance ratio outside ratio limits has been recalculated according to method requirements.
Page No. 1 Listing of WOOSSllB.dbf 01/10/2002 Matched GC Peaks Z Ratio / Ret. Time
Compound/ QC.Log Omit V.'hy ..RT. OK Ratio Total .Area/Ht Area/Ht. Peakl Area/Ht. Peak2 Fel.RT Compound. Name. . id,. Flags.
TCDF 0.65-0.89 0.873-1.075 304-306 DC NL Height 11.18 7.55 3.63 DC SN 25:13 RO 1.13 30.04 0,972 DC SN 25:33 RO 0.51 33.61 0.905 1270-TCDF AN 25:57 0.77 1,746.49 759.97 986.52 1.001 237e-TCDF AN 104-306 1 Peak 1,746.49
13C12-TCDF 0.65-0.89 0.961-1.039 316-318 DC NL Height 5.06 2.55 2.51 25:32 0.6B 93.5B 37.78 55.80 0.985 25:56 0.75 18,640.06 7,975.46 10,664.60 1.000 13C12-237B-TCDr ISO Height 5,049.66 2,163.48 2,886.18 316-318 2 Peaks 18.733.64
Above: TCDF / TCDD Follows
TCDD 0.65-0.89 0.900-1.0J4 320-322 DC NL Height 4.17 1.97 2,20 DC SNI 24:49 RO 1.03 9.45 0.931 DC SNI 25:10 RO 1.74 4.09 0.944 DC SNi 25:17 RO 1.02 4.83 0.949 DC SN 26:29 RO 1.01 10.14 0.994 26:41 0.73 1,464.21 619.02 845.19 1.001 237e-TCDD AN DC SN' 26:53 RO 0.52 e.39 1.009 DC SN' 27,-29 RO 1.24 5.17 1.031 320-322 1 Peak 1,464.21
37C1-TCDD 0.925-1.075‘’ 328 DC NL Height 2.20 2.20 DC SN 24:46 4.08 0.929 DC SN 24:53 1.37 0.934 DC SN 25:00 1.39 0.930 DC SN 25:06 4.83 0.942 DC SN 25:24 8.10 0.953 ' DC SN 25:32 2.19 0.958 DC SN 25:39 1,35 0.962 26:41 1.383.43 1.363.43 1.001 37C1-TCDD CLS DC SN 26:53 6.13 1.009 DC SN 27:09 1.97 1.019 DC SN 27:12 0. 61 1.021 DC SN 27:13 0.94 1.021 27:19 10.25- 10.25 1.025 27:32 6.03 6 ,C3 1.033 DC SN 27:37 2.30 1.036
Triangle Laboratories, Inc.® 801 Capitola Drive • Durham, North Carolina 27713 Printed; 01:0^ ^140/2002 ' Phone: (919) 544-5729 • Fax: (919) 544-5491
CITY_21MC100_003110334
NYC-WTC_000278233
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000278249
Laboratory report for PCDD/PCDF analysis (dioxin) from NYC WTC area samples, Jan 2002.
4 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278209
Laboratory report for PCDD/PCDF analysis (dioxin) from NYC WTC area samples, Jan 2002.
4 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186387
Laboratory report detailing PCDD and PCDF analysis results for a wipe sample from the NYC WTC area.
3 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278126
Laboratory report for PCDD/PCDF analysis (dioxin) from NYC WTC area samples, Jan 2002.
3 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304968
Matched GC peaks and ratios for SO20236B, Jan 2002.
3 shared non-person entities · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304905
Matched GC peaks and ratios for W010210B with QC checks, Jan 2002.
3 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304793
Listing of GC peaks, relative retention times, and TCDF/TCDF-related data.
3 shared non-person entities · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304984
Matched GC peaks and ratios for S020237B, Jan 2002.
3 shared non-person entities · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186318
Laboratory report detailing PCDD and PCDF analysis results for a gauze sample from the NYC WTC area.
3 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278148
Laboratory report for PCDD/PCDF analysis (dioxin) from NYC WTC area samples, Jan 2002.
4 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278171
Laboratory report for PCDD/PCDF analysis (dioxin) from NYC WTC area samples, Jan 2002.
4 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278318
Laboratory results for TCDD/TCDF analysis on NYC WTC area sample, Jan 2002.
3 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000304984
Matched GC peaks and ratios for S020237B, Jan 2002.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304905
Matched GC peaks and ratios for W010210B with QC checks, Jan 2002.
Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186346
Laboratory report detailing PCDD and PCDF analysis results for a wipe sample from the NYC WTC area.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278249
Laboratory report for PCDD/PCDF analysis (dioxin) from NYC WTC area samples, Jan 2002.
Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304793
Listing of GC peaks, relative retention times, and TCDF/TCDF-related data.
Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304930
Matched GC peaks, ratios, ret times for P020118B, Jan 2002.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000278249
Laboratory report for PCDD/PCDF analysis (dioxin) from NYC WTC area samples, Jan 2002.
Similar indexed content
NYC-WTC_000278209
Laboratory report for PCDD/PCDF analysis (dioxin) from NYC WTC area samples, Jan 2002.
Similar indexed content
NYC-WTC_000186387
Laboratory report detailing PCDD and PCDF analysis results for a wipe sample from the NYC WTC area.
Similar indexed content
NYC-WTC_000278126
Laboratory report for PCDD/PCDF analysis (dioxin) from NYC WTC area samples, Jan 2002.
Similar indexed content
NYC-WTC_000304968
Matched GC peaks and ratios for SO20236B, Jan 2002.
Similar indexed content