Air sampling letter, HS for Leadership

Machine-extracted title · confidence 39%

ATC letter reporting air sampling results for PCDD/PCDF at school.

NYC-WTC_000298163–000298165
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan January 30, 2002 Air Sampling for Dioxins Page 2 H. S. for Leadership & Public Service (894M) ATC Project No. 15-19125-0290

Combustion of PCB-containing oils, such as during an electrical transformer fire, is known to produce dioxins. Burning of some plastics may also produce dioxins. Dioxins are toxic and are considered to be carcinogenic.

The Environmental Protection Agency (EPA) has a screening level for dioxins in air of 0.16 nanograms per cubic meter (0.16 ng/m’). A nanogram is a thousandth of a microgram (1 X 10’’ gram). The EPA screening level is based on continuous exposure for one year. The Occupational Safety and Health Administration (OSHA) has not established a Permissible Exposure Limit (PEL) for dioxins in air.

RESULTS

Each sample was analyzed for seventeen (17) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value for the analytical results for each sample.

The results for both days are summarized in the table. A picogram is one one-thousandth of a nanogram (10 *^ gram).

AIRBORNE DIOXIN LEVELS (2,3, 7,8 TCDD EQUIVALENTS)

Lobby 13“ Floor 0.0030

Lobby Main Entrance 0.021

3'“ Floor Hallway North Stairs 0.0034

11“ Floor Room 1106 South 0.0024

Room 503 5“ Floor North 0.0039

Room 715 7“ Floor South 0.0011

Room 903 9“ Floor North 0.0013

Roof by Air Intake 0.0028

Outdoors by Main 0.0019 Entrance Lab Blank 0.000050

CITY_21MC100_012155596

NYC-WTC_000298164

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000298164Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →