Mr. Bernard P. Orlan April 26, 2002 Air Sampling for Metals Page 2 H.S. for Leadership & Pub. Service (894M) ATC Project No, 15-19125-0290

Results

March 15

Chromium (Cr), iron (Fe) and lead (Pb) were found above the limits of detection, Cr and Pb were also detected in the blank. Subtracting the Cr content of the blank from concentrations in the samples reduces those concentrations by approximately 50% to 0.00016 - 0.000315 mg/m^. Blank-correcting the Pb concentrations lowers them to below the limit of detection. Fe was detected in two samples (Main Lobby, Ml and Roof, M4) at 0.00177 and 0.00147 mg/m\

March 22

Cr was detected in all four samples, Pb and Fe were detected in one sample. Cr and Fe were detected in the blank. Blank-correcting the Cr and Pb concentrations in the samples lowers them to below or just above the limits of detection, Fe was detected in the Main Lobby sample (Ml) at 0,00171 mg/m^

March 29

The only metal detected was Cr, however blank-correcting the Cr concentrations in the samples lowers them to below the limit of detection.

The Environmental Protection Agency (EPA) has set a screening level for hexavalent chromium (the more toxic form) in air of 0.6 micrograms per cubic meter of air (ug/nY). this assumes a continuous exposure for one year. The samples here were analyzed for total chromium (trivalent and hexavalent).

The EPA has an ambient air standard for Pb of 1.5 ug/m^, based on a three-month exposure.

The EPA has no screening level or standard for Fe in ambient air.

ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.

Sincerely, ATC Associates, Inc.

James R, Cohn, CIH, CSP Regional Manager Industrial Hygiene Division

Attachment

CITY_21MC1OO_OO3O864O8

NYC-WTC_000296646

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000296646Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000175577

Letter report detailing air sampling for metals conducted at the High School for Leadership on dates in March 2002.

Similar indexed content

NYC-WTC_000384699

ATC report of metals air sampling at the High School of Economics and Finance.

Similar indexed content

NYC-WTC_000259700

ATC reports air sampling for metals conducted in March 2002 at the referenced NYC BOE school.

Similar indexed content

Compare copies and versions →