NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Air sampling for metals, High School of Economics

Machine-extracted title · confidence 25%

ATC report of metals air sampling at the High School of Economics and Finance.

NYC-WTC_000384699–000384700
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan April 29,2002 Air Sampling for Metals Page 2 H.S. of Economics & Finance ( 833M ) ATC Project No. 15-19125-0291

Results

March 9

Chromium (Cr) was detected in all four samples and in the blank. Blank-correcting the Cr concentrations lowers them to below or just above the limit of detection.

The only other metal found was iron (Fe) which was detected at 0.00231 milligrams per cubic meter (mg/m") in the sample collected on the Roof (#M4).

March 16

The metals detected were Cr, Fe and lead (Pb). Cr was found in one sample and in the blank at approximately the same concentration. Fe was detected in the sample collected in the Main Lobby ((#M1) at 0.000273 mg/m’, it was not present in the other samples or in the blank.

Pb was detected in all four samples and in the blank. The blank-conected Pb concentrations are all below the limit of detection.

March 23

Cr was detected in all four samples and in the blank. The blank-corrected Cr concentration was greater than the limit of detection only in the sample collected in the 10* floor hallway (#M3). The Cr concentration in this sample was 0.00026 mg/m\

The only other metal detected was copper (Cu). Cu was detected in the roof sample at a concentration of 0.000334 mg/m’. Cu was not detected in the other samples or in the blank.

The Environmental Protection Agency (EPA) has set a screening level for hexavalent chromium (the more toxic form) in air of 0.6 ug/m\ this assumes a continuous exposure for one year. The samples here were analyzed for total chromium (trivalent and hexavalent).

The EPA’s ambient air standard for Pb is 1.5 ug/m’ (three-month average). The EPA has no screening level or standard for Cu in ambient air.

ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.

Sincerely, ATC Associates, Inc.

James R. Cohn, CIH, CSP Regional Manager, Industrial Hygiene Division

Attachment

CITY_21MC100_002881840

NYC-WTC_000384700

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000384700Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000259700

ATC reports air sampling for metals conducted in March 2002 at the referenced NYC BOE school.

Similar indexed content

NYC-WTC_000384714

ATC provides air metals sampling results for the High School of Economics and Finance (833M).

Similar indexed content

NYC-WTC_000259686

ATC reports multi-day air sampling for metals at a NYC high school, requested by the BOE in June 2002.

Similar indexed content

Compare copies and versions →