NYC-WTC_000295919
March 25, 2002 IAQ measurements at School for Leadership & [name], NYC BOE.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗ATC report on indoor air quality measurements at NYC school; March 14, 2002.
NYC-WTC_000295866–000295869OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr Bernard P Orlan March 15 2002 Indoor Air Quality Assessment Page 4 H S for Leadership & Public Service fM894) ATCProiectNo 15 19125 0290 * The measurements made during this assessment were instantaneous readings the NPAAQS is a 24 hour average
TVOC Concentration
The TVOCs concentrations were 0 ppm inside the building These concentrations were below the AIHA guideline for odor control of 1 ppm The outdoor TVOC concentration was also 0 ppm
OBSERVATIONS
During this assessment ATC noted the following • The mtenor of the building appeared clean and free of dust and debris • The building was occupied at the time of the assessment • No smoke odor was detected in the building
FINDINGS
Based on the real time measurements the following findings are presented
1 Concentrations of CO2 CO and TVOCs were below applicable standards and guidelines 2 Sixteen (16) indoor measurement for temperature were within the range and one hundred seventy two (172) measurements were above the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55 1992 dunng the heating season (wintertime conditions) 3 Three (3) of the indoor measurements for relative humidity were below and one hundred eighty five (185) were within the ASHRAE recommended range of 30 to 60 percent for occupant comfort 4 All of the indoor measurements were below the NPAAQS of 65 pg/m^ 24 hour average concentration of particulate matter 2 5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration for sensitive individuals such as asthmatic people and children of 40 pg/m^ All of the outdoor measurements were above the NPAAQS of 65 pg/m^ 24 hour average concentration of particulate matter 2 5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration for sensitive individuals such as asthmatic people and children of 40 pg/m^
It IS our pleasure to provide these indoor air quality services to the New York City Board of Education If you have any questions about this report please call (212) 353 8280 extension 336 or 212
^ncerely Reviewed by MTC ASSOCIA TES INC
'^meMaral James R Cohn CIH CSP Senior woject Manager Regional Manager Industrial Hygiene Division Attachment
CITY_21MC100_003085453
NYC-WTC_000295869
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000295919
March 25, 2002 IAQ measurements at School for Leadership & [name], NYC BOE.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295915
March 22, 2002 IAQ measurements at School for Leadership & [name], NYC BOE.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295749
ATC memo describing IAQ measurements at the referenced NYC school.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295745
ATC memo about IAQ measurements at a NYC school for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295726
ATC Associates memo documenting indoor air quality measurements at a NYC school.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295792
ATC report on IAQ measurements conducted at the referenced NYC school.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295768
ATC report of IAQ measurements at a NYC school for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297874
ATC report of IAQ measurements collected on Feb 28, 2002 at the referenced school.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295787
ATC report detailing IAQ measurements at NYC school; March 7, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295811
ATC report of IAQ measurements at NYC school; March 11, 2002.
11 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297826
ATC report of IAQ measurements collected Feb 15, 2002 at the referenced school.
12 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000350853
DOE-DOE indoor air quality assessment report for PS 126M 80.
10 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000295919
March 25, 2002 IAQ measurements at School for Leadership & [name], NYC BOE.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295915
March 22, 2002 IAQ measurements at School for Leadership & [name], NYC BOE.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000175529
Report from ATC Associates detailing indoor air quality measurements collected at a New York City Department of Education school.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000309219
September 2002 IAQ report for PS 124M school.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000177858
Cover letter and report detailing indoor air quality measurements collected at PS 234M on January 29, 2002, to evaluate building contamination.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239839
Report of indoor air quality measurements collected at PS 124M in September 2002 to verify acceptable air conditions.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000295919
March 25, 2002 IAQ measurements at School for Leadership & [name], NYC BOE.
Similar indexed content
NYC-WTC_000295915
March 22, 2002 IAQ measurements at School for Leadership & [name], NYC BOE.
Similar indexed content
NYC-WTC_000295749
ATC memo describing IAQ measurements at the referenced NYC school.
Similar indexed content
NYC-WTC_000295745
ATC memo about IAQ measurements at a NYC school for BOE.
Similar indexed content
NYC-WTC_000295726
ATC Associates memo documenting indoor air quality measurements at a NYC school.
Similar indexed content