Mr Bernard P Orlan September 11, 2002 Indoor Air Quality Assessment Page 4 PS 124 M ATCProiectNo 15-19125-0350

* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average

TVOC Concentration

TVOCs concentrations indoors ranged from 0 ppm to 0 1 ppm The AIHA guideline for odor control IS 1 ppm The outdoor TVOC concentrations were 0 5 ppm and 0.6 ppm

OBSERVATIONS

During this assessment, ATC noted the following

• The building was occupied, • The building has no central HVAC

FINDINGS

Based on the real-time measurements, the following findings are presented'

1. Concentrations of CO2, CO and TVOCs were within applicable standards and guidelines. 2. Eighteen (18) of the indoor temperature measurements were above the range of 73 to79 °F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the summer season 3. All of the indoor measurements for relative humidity were within the ASHRAE- recommended range of 30 to 60 percent for occupant comfort 4. Fourteen (14) of the indoor measurements for PM2 5 were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals such as asthmatic people and children. None of the indoor measurements were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2 5 micrometers or less in aerodynamic diameter

It IS our pleasure to provide these indoor air quality services to the New York City Department of Education If you have any questions about this report, please call (212) 353-8280, extension 211 or 212

Sincerely, A TC ASSOCIA TES INC. Reviewed By

'i /Ylannis Efstathioi/'' James R Cohn, CIH, CSP Senior Project Manager Regional Manager, Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_2IMCl00_003431399 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000175532

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000175532Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Indoor air quality report, PS 234M, Jan 2002

NYC-WTC_000177858

Cover letter and report detailing indoor air quality measurements collected at PS 234M on January 29, 2002, to evaluate building contamination.

Similar indexed content

Compare copies and versions →