NYC-WTC_000314825
IAQ measurements collected March 18, 2002 at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗ATC IAQ report for PS 234M, measurements collected March 18, 2002.
NYC-WTC_000294438–000294441OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan March 19, 2002 Indoor Air Quality Assessment Page 4 P. S. 234M ATC Project No. 15-19125-0279
The average PM2.5 concentration for the entire school building was approximately 10 pg/m^. The outdoor respirable particulate concentration ranged from 18 to 23 pg/m^ with an average of 20 pg'm3.
* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
TVOC Concentration
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm. OBSERVATIONS
During this assessment, ATC noted the following: • The building was occupied at the time of the assessment; • No smoke odor was detected in the building.
FESDINGS
Based on the real-time measurements, the following findings are presented;
1. Concentrations of CO .CO^and TVOCs were within applicable standards and guidelines. 2. One (1) indoor measurement for temperature was below the range of 68 to 75°F (at 50 percent relative humidity) as recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). 3. Twenty-five (25) of the indoor measurements for relative humidity were below the ASHRAE-recomraended range of 30 to 60 percent for occupant comfort. 4. None of the indoor or outdoor measurements for PM2.5 were above the NPAAQS of 65 pg/m3 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Also none of the measurements were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals / children.
It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 211 or 212.
Sincerely, ATC ASSOCIATES INC. Reviewed by:
Yiannis Efstathiou James R. Cohn, CIH, CSP Senior Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CITY_21MC100_003083671
NYC-WTC_000294441
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000314825
IAQ measurements collected March 18, 2002 at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294472
Indoor air quality measurements at PS 234M, documenting March 22, 2002 activities.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397261
IAQ measurements report for PS 234M; April 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000371824
ATC IAQ measurements report prepared for BOE at PS 234M in April 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397251
IAQ measurements report for P.S. 234M, Apr 2002; scope of work described.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314964
Indoor air quality measurements collected at P.S. 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314985
Indoor air quality measurements collected at P.S. 234M.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314815
IAQ measurements collected March 19, 2002 at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000381400
ATC IAQ field report for PS 234M, March 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294458
Indoor air quality measurements at PS 234M, prepared for NYC BOE, March 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397291
IAQ measurements at PS 234M; BOE requested assessment of air quality.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397241
Indoor air quality measurements report for P.S. 234M, Apr 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000371824
ATC IAQ measurements report prepared for BOE at PS 234M in April 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000371814
ATC report of IAQ measurements conducted April 9, 2002 at P.S. 234M for BOE review.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314825
IAQ measurements collected March 18, 2002 at PS 234M for BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397241
Indoor air quality measurements report for P.S. 234M, Apr 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314964
Indoor air quality measurements collected at P.S. 234M for BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314954
Air quality measurements collected at P.S. 234M for BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000314825
IAQ measurements collected March 18, 2002 at PS 234M for BOE.
Similar indexed content
NYC-WTC_000294472
Indoor air quality measurements at PS 234M, documenting March 22, 2002 activities.
Similar indexed content
NYC-WTC_000397261
IAQ measurements report for PS 234M; April 2002.
Similar indexed content
NYC-WTC_000371824
ATC IAQ measurements report prepared for BOE at PS 234M in April 2002.
Similar indexed content
NYC-WTC_000397251
IAQ measurements report for P.S. 234M, Apr 2002; scope of work described.
Similar indexed content