Mr. Bernard P. OrIan April 11,2002 Indoor Air Quality Assessment Page 4 P. S. 234M ATC Project No. 15-19125-0279 The average PM2.5 concentration for the entire school building was approximately 20 pg/m^. The outdoor respirable particulate concentration ranged from 19 to 28 pg/m^ with an average of 23 pg/m3.
* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
TVOC Concentration
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm. OBSERVATIONS
During this assessment, ATC noted the following: • The building was occupied at the time of the assessment; • No smoke odor was detected in the building.
FINDINGS
Based on the real-time measurements, the following findings are presented:
1. Concentrations of CO ,CO2and TVOCs were below applicable standards and guidelines. 2. All indoor measurements for temperature were within the range of 68 to 75°F (at 50 percent relative humidity) as recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). 3. Ten (10) indoor measurements for relative humidity were below and forty (40) were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. 4. None of the indoor or outdoor measurements for PM2.5 were above the NPAAQS of 65 pg/m3 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Also none of the instantaneous measurements (indoors and outdoors) were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children.
It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 211 or 212.
Sincerely, A TC ASSOCIA TES INC. Reviewed by:
y/^^es R. Cohn, CIH, CSP
Senior Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CITY_21MC100_003032211
NYC-WTC_000314967
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000397261
IAQ measurements report for PS 234M; April 2002.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000371824
ATC IAQ measurements report prepared for BOE at PS 234M in April 2002.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397251
IAQ measurements report for P.S. 234M, Apr 2002; scope of work described.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314985
Indoor air quality measurements collected at P.S. 234M.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314825
IAQ measurements collected March 18, 2002 at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397241
Indoor air quality measurements report for P.S. 234M, Apr 2002.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397291
IAQ measurements at PS 234M; BOE requested assessment of air quality.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314954
Air quality measurements collected at P.S. 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294472
Indoor air quality measurements at PS 234M, documenting March 22, 2002 activities.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314989
INS IAQ measurements collected at P.S. 234M; BOE referenced.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294458
Indoor air quality measurements at PS 234M, prepared for NYC BOE, March 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314815
IAQ measurements collected March 19, 2002 at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000397261
IAQ measurements report for PS 234M; April 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314825
IAQ measurements collected March 18, 2002 at PS 234M for BOE.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294482
Indoor air quality measurements collected March 26, 2002 at the referenced school.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314985
Indoor air quality measurements collected at P.S. 234M.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397241
Indoor air quality measurements report for P.S. 234M, Apr 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000371824
ATC IAQ measurements report prepared for BOE at PS 234M in April 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000397261
IAQ measurements report for PS 234M; April 2002.
Similar indexed content
NYC-WTC_000371824
ATC IAQ measurements report prepared for BOE at PS 234M in April 2002.
Similar indexed content
NYC-WTC_000397251
IAQ measurements report for P.S. 234M, Apr 2002; scope of work described.
Similar indexed content
NYC-WTC_000314985
Indoor air quality measurements collected at P.S. 234M.
Similar indexed content
NYC-WTC_000314825
IAQ measurements collected March 18, 2002 at PS 234M for BOE.
Similar indexed content