NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Indoor air quality report, PS 234M, Mar 2002

Machine-extracted title · confidence 41%

IAQ measurements collected March 9–11, 2002 for PS 234M at Greenwich st school.

NYC-WTC_000294397–000294400
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan March 11,2002 Indoor Air Quality Assessment Page 4 P. S. 234M ATCProiectNo. 15-19125-0279 measurements were above the EPA recommended guideline of 40p,g/m3 for children and sensitive individuals.

* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.

Type Concentration

TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm. OBSERVATIONS

During this assessment, ATC noted the following: • The building was occupied at the time of the assessment; • No smoke odor was detected in the building-

FINDINGS

Based on the real-time measurements, the following findings are presented:

1. Concentrations of CO and TVOCs were within applicable standards and guidelines. 2. One (1) indoor temperature measurements was below and seven (7) indoor measurements were above the range of 68 to 75°F (at 50 percent relative humidity) as recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). 3. Forty-nine (49) of the indoor relative humidity measurements were within and one (1) measurement was below the ASHRAE-recommended range of 30 to 60 percent for occupant comfort.,. 4. Thirty-three (33) of the indoor carbon dioxide measurements were above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. 5. Fifteen (15) indoor respirable measurements were above the NPAAQS of 65 pg/m3 • Forty- five (45) of the fifty (50) instantaneous indoor measurements and all of the instantaneous outdoor readings were above the EPA recommended guideline of dOpg/m^ for children and sensitive individuals.

It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 211 or 212.

Sincerely, J TC ASSOCIA TES INC. Reviewed by:

TTimes R. Cohn, CIH, CSP lect Manager Regional Manager, Industrial Hygiene Division

Attachment

CITY_21MC100_003083622

NYC-WTC_000294400

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000294400Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →