NYC-WTC_000340253
TEM analysis of air samples from HS for Economics & Finance; TEM/SAED/EDS results.
5 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗TEM analysis details for Stuyvesant HS with diffusion and volume data.
NYC-WTC_000294143OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, ERA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Satvtple Z^dentification Analysis Parameters
Project/Site: Stu-^/vesant H .S. , 345 Chambers St.,, NY, NY TEM Sample Nc.: S609 60021 Floors 1-10 Date Received: 10/05/01 Grid Openings Analysed;__ 4
Project Sample No . SHS-1?10-10/5-14 •Average Grid Opening: 106.00 um
Air Volume: 1853 liters Total Area Analyzed;0 04 5 0 mni2
Filter Type: MCE 25 mm diant , Pore Size; 0.45 um Analytical Sensitivity : 2 2 iJ s2mn^ Effective Area: 385mm2 0.0Q46 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct Struct >=5um Struct/mm2 Struct/cc ngTn/m3
Chrysocile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.Q 0.0000 0
Total asbestos {includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos T-ype: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by. Report Reviewed by:
Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003082880
NYC-WTC_000294143
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000340253
TEM analysis of air samples from HS for Economics & Finance; TEM/SAED/EDS results.
5 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270586
TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.
5 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294146
TEM analysis report for Stuyvesant HS, including air volume and sample diameter.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293691
TEM fiber analysis and diffraction/EDS report for a school site, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270124
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330166
TEM analysis record for multiple samples; batch and project refs.
5 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340268
Asbestos TEM analysis (SAED/EDS) for HS project site, Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411537
TEM asbestos analysis details for PS 234M project, October 2001.
5 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330170
TEM/SAED/EDS data for project site asbestos analysis.
5 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340260
Asbestos TEM analysis (SAED/EDS) for HS project site, Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270116
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294059
TEM asbestos fiber analysis from Stuyvesant High School samples, Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000340253
TEM analysis of air samples from HS for Economics & Finance; TEM/SAED/EDS results.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270586
TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294146
TEM analysis report for Stuyvesant HS, including air volume and sample diameter.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293691
TEM fiber analysis and diffraction/EDS report for a school site, Oct 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270124
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330166
TEM analysis record for multiple samples; batch and project refs.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000340253
TEM analysis of air samples from HS for Economics & Finance; TEM/SAED/EDS results.
Similar indexed content
TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.
Similar indexed content
NYC-WTC_000294146
TEM analysis report for Stuyvesant HS, including air volume and sample diameter.
Similar indexed content
NYC-WTC_000293691
TEM fiber analysis and diffraction/EDS report for a school site, Oct 2001.
Similar indexed content
NYC-WTC_000270124
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
Similar indexed content