NYC-WTC_000294146
TEM analysis report for Stuyvesant HS, including air volume and sample diameter.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗TEM asbestos fiber analysis from Stuyvesant High School samples, Oct 2001.
NYC-WTC_000294059OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: MERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Anal3:;si^Pararneters
Project/Site: gtuyvesant H,S., 34S Chambers St., NY, NY TEM Sample No.: 5609 - 60043 Floors 1-10 Date Received: 10/05/01 Grid Openings Analyzed;__ 4
Project Sample No.: SHS-l>10-10/5-36 Average Grid Opening-: 106.00 um
Air Volume-. 19 6 2 liters Total Area Analyzed: 0,0450 mm2
Filter Type: MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity Effective Area: 385 mm2 0 ■ 0046 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/in3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0. 0 0.0000 0
Total asbestos {includes ambiguous structures! 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 c 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type; None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by; Report Reviewed dy:
Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003082787
NYC-WTC_000294059
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000294146
TEM analysis report for Stuyvesant HS, including air volume and sample diameter.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294141
TEM analysis parameters for Stuyvesant HS project (opening and air volume).
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270586
TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270091
Asbestos TEM analysis on Stuyvesant HS samples with SAED/EDS, Oct 1997.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270116
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330170
TEM/SAED/EDS data for project site asbestos analysis.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330204
TEM asbestos analysis with SAED/EDS for NYC project, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411537
TEM asbestos analysis details for PS 234M project, October 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340260
Asbestos TEM analysis (SAED/EDS) for HS project site, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293691
TEM fiber analysis and diffraction/EDS report for a school site, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411477
TEM asbestos analysis report for 328 W. 14th St. site dating Sept 28, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270110
Asbestos fiber analysis by TEM (AHERA method) for Stuyvesant HS, floors 1-10, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000294146
TEM analysis report for Stuyvesant HS, including air volume and sample diameter.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294141
TEM analysis parameters for Stuyvesant HS project (opening and air volume).
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270586
TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270091
Asbestos TEM analysis on Stuyvesant HS samples with SAED/EDS, Oct 1997.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270116
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330170
TEM/SAED/EDS data for project site asbestos analysis.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000294146
TEM analysis report for Stuyvesant HS, including air volume and sample diameter.
Similar indexed content
NYC-WTC_000294141
TEM analysis parameters for Stuyvesant HS project (opening and air volume).
Similar indexed content
TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.
Similar indexed content
NYC-WTC_000270091
Asbestos TEM analysis on Stuyvesant HS samples with SAED/EDS, Oct 1997.
Similar indexed content
NYC-WTC_000270116
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
Similar indexed content