NYC-WTC_000293944
TEM analysis of air samples at New Stuyvesant HS, exterior/interior, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗TEM asbestos fiber analysis for New Stuyvesant High School exterior/interior, received 10/25/01.
NYC-WTC_000293948OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document I
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/25/01
ASBESTOS FIBER TkNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Proj ect/Site; New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5766 62348 Exterior & Interior of Building & Roof Date Received: 10/25/01 Grid Openings Analyzed:__ 4
Project Sample No.: 16 Average Grid Opening: 106,00 um
Air Volume ; 1928 ]J^t^^ Total Area Analyzed ;0^04£^0 mn^
Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity:22;.2 s/mm2 Effective Area: 385 mm2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 C 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos {includes ambiguous structures) 0 0 0. 0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) C 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003082660
NYC-WTC_000293948
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000293944
TEM analysis of air samples at New Stuyvesant HS, exterior/interior, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270979
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293970
TEM analysis; New Stuyvesant HS project; received 10/26/01.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293900
TEM analysis with structure ID and EDS; exterior/interior building data.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188695
TEM laboratory report detailing asbestos fiber counts and structural identification for air samples from a NYC education facility.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182602
Technical data sheet recording air volume and microscopic analysis parameters for exterior and interior samples at Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270873
TEM asbestos analysis with AHERA/ERA methods; sample 4 for New Stuyvesant HS.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188631
Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293448
TEM analysis data for NSHS; exterior/interior openings documented.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188696
Laboratory report presenting transmission electron microscopy results for asbestos fibers collected during an inspection of a high school.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294008
TEM analysis of air samples at New Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188694
Document containing transmission electron microscopy data for asbestos fiber identification in air samples from a high school building.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000293944
TEM analysis of air samples at New Stuyvesant HS, exterior/interior, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270979
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293970
TEM analysis; New Stuyvesant HS project; received 10/26/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293900
TEM analysis with structure ID and EDS; exterior/interior building data.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188695
TEM laboratory report detailing asbestos fiber counts and structural identification for air samples from a NYC education facility.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182602
Technical data sheet recording air volume and microscopic analysis parameters for exterior and interior samples at Stuyvesant High School.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM analysis of air samples at New Stuyvesant HS, exterior/interior, Oct 2001.
Similar indexed content
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.
Similar indexed content
TEM analysis; New Stuyvesant HS project; received 10/26/01.
Similar indexed content
TEM analysis with structure ID and EDS; exterior/interior building data.
Similar indexed content
NYC-WTC_000188695
TEM laboratory report detailing asbestos fiber counts and structural identification for air samples from a NYC education facility.
Similar indexed content