NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM analysis, New Stuyvesant H.S. exterior/interior

Machine-extracted title · confidence 30%

TEM analysis of New Stuyvesant HS air samples, exterior/interior, Oct 2001.

NYC-WTC_000293942
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document I

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: lO/25/Ol

ASBESTOS FIBER TUSTALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR. Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Paratr.eters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5766 62342 Exterior & Interior of Building & Roof Date Received: 10/25/01 Grid Openings Analyzed:__ 4

Project Sample No.: 10 Average Grid Opening: 106.00 um

Air Volume: 1944 liters Total Area Analyzed :0;0450 mm2

Filter Type :_J:lCE_25_j2nL_diamn__,__Pore_Si2ej__^^ Analytical Sensitivity:22;2 s/rrim2 Effective Area :385 rnm2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct Sum Struct/mni2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 C 0 0 0 0.0 0.0000 0

Ambiguous 0 0 C 0 0 0 0.0 0.0000 0

Total asbestos {includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 C 0 0 0 0.0 0.0000 N/A No Identification 0 0 C 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003082654

NYC-WTC_000293942

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293942Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293972

TEM analysis; exterior/interior; received 10/26/01.

Similar indexed content

NYC-WTC_000270876

TEM asbestos analysis; exterior/interior of building, sample 9.

Similar indexed content

NYC-WTC_000270708

TEM/SAED/EDS asbestos analysis for New Stuyvesant HS exterior & interior.

Similar indexed content

Compare copies and versions →