ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: .10/23/01

ASBESTOS FIBER TUSTALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: MERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

- Sample Identification AnaJysisParamete^

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5739- 61939 Ex-terior & Interior of Building & Roof Date Received: 10/22/01 Grid Openings Analyzed:__ 4

Project Sample No. Average Grid Opening: 106,00 urn

ALr Volume: 1936 liters Total Area Analyzed :0;04^0 mm2

Filter Tvpe-. MCE 25 mm diam. Pore Size-. 0.4 5 um Analytical Sensitivity 22.2 s/mm2 Effective Area: 385 mm2 0.0044 s/cc

FIBROUS PARTICULATES TkNALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 ’0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED) : None'detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by. Report Reviewed by;

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003099704

NYC-WTC_000270708

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270708Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270876

TEM asbestos analysis; exterior/interior of building, sample 9.

Similar indexed content

NYC-WTC_000293972

TEM analysis; exterior/interior; received 10/26/01.

Similar indexed content

NYC-WTC_000293942

TEM analysis of New Stuyvesant HS air samples, exterior/interior, Oct 2001.

Similar indexed content

NYC-WTC_000270723

TEM analysis with SAED/EDS for New Stuyvesant High School, received 10/22/01.

Similar indexed content

Compare copies and versions →