Asbestos TEM analysis, New Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 41%

TEM analysis of Building & surroundings; SAED/EDS; sample 5739, Received 10/22/01.

NYC-WTC_000293819
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document I

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/23/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 7631, Vol. 52, No. 210, October 30, 1987

SamKile Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: S739 61554 Exterior & Interior of Building & Roof Date Received:10/22201 Grid Openings Analyzed;__ 4

Project Sample No.: 19 Average Grid Opening; 106.00 urn

Air Volume :1952]Ate^ Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam., Pore Size; 0.45 urn Analytical Sensitivity: Effective Area: 385 mrn2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >^5um Struct/mm2 Struct/cc ngrn/m3

•Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0. 0 0.0000 0

Ambiguous 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) c 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 c 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100^003082518

NYC-WTC_000293819

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293819Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293850

Asbestos fiber TEM analysis with SAED/EDS for New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000293812

Asbestos TEM analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000292744

TEM asbestos analysis by TEM with SAED/EDS for New Stuyvesant H.S., Oct 29, 2001.

Similar indexed content

NYC-WTC_000270675

TEM-based asbestos fiber analysis for New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000270808

TEM asbestos analysis for New Stuyvesant High School exterior/interior, received 10/24/01.

Similar indexed content

Compare copies and versions →