NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, New Stuyvesant H.S., 10/29/01

Machine-extracted title · confidence 63%

TEM asbestos analysis by TEM with SAED/EDS for New Stuyvesant H.S., Oct 29, 2001.

NYC-WTC_000292744
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/29/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Fart 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/SiCe: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5785 62411 Exterior Interior of Building & Roof Date Received: 10/28/01 Grid Openings Analyzed:__ 4

Project Sample No.:_2 Average Grid Opening: 106.00 um

Air Volume :1936 nters Total Area Analyzed: D.0450 mm2

Filter Type; MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity :22;2 s/mrn2 Effective Area: 385 mm2 0■0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct '.sc.nm Struct/mm2 Etruct/cc ngm/ml

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0 . 0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0 . 0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003081411

NYC-WTC_000292744

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000292744Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293901

TEM data with air volume and analysis parameters for building sample.

Similar indexed content

NYC-WTC_000292752

TEM analysis with air volume and opening details for exterior/interior of New Stuyvesant H.S., 10/28/01.

Similar indexed content

NYC-WTC_000270670

TEM analysis of asbestos fibers at New Stuyvesant H.S. with SAED/EDS, Oct 2001.

Similar indexed content

Compare copies and versions →