ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/18/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) with Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy lEDS; Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763;, Vol. 52, No. 210, October 30, 1987

Sample Idgntifxcation Analysis Parameters

Prcject/Site -. New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No. .- 5725 61648 Exterior & Interior of .Building & Roof Date Received: 10/18/01 □rid Openings Analyzed:__4

Project Sample No.: 16 Average Grid Opening: 106.00 urn

Air Volume: 1920 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam. Pore Size: 0.45 urn Analytical Sensitivity: 22^2 s/miTi2 Effective Area: 385 mm2 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mrn2 Struct/cc ngm/m3

Chrysotile Asbestos 0 C 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0 . GOOD 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.cooo 0 Non-Asbestos 0 0 0 0 0 0 0.0 0 . cooo n7a No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. {EDS/SAED); None detected Amphibole Asbestos Type; None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by;

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003082323

NYC-WTC_000293647

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293647Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293853

Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.

Similar indexed content

NYC-WTC_000270537

TEM asbestos analysis for exterior & interior of New Stuyvesant High School; includes SAED/EDS method and date.

Similar indexed content

NYC-WTC_000270916

TEM-based asbestos fiber analysis for New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000293495

Asbestos fiber analysis by TEM on exterior/interior samples from New Stuyvesant High School, received 10/13/01.

Similar indexed content

Compare copies and versions →