NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM report, New Stuyvesant H.S., exterior/interior

Machine-extracted title · confidence 31%

TEM analysis report for New Stuyvesant High School building exterior and interior, 10/24/01.

NYC-WTC_000270751
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

.N.Y.C. Board of Education Approved N.Y. State ELAP. #10879 ■ 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 ' • Long Island City, NY 11101 Report Date: 10/24/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) with Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy lEDS) Method; AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987,

Sample Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No'. : 5748 - 62056 Exterior & Interior of Building & Roof Date Received; 10/23/01 Grid Openings Analyzed:__ 4

Project Sample No.: 2 Average Grid Opening: 106.00 urn

Air Volume:19363Aters Total Area Analyzed: 0.0450 mm2

Filter Typ e: .MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity: 22.2 s/mm2 Effective Area: 385 mm2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total single Matrix Total. Struct, Filter Air Fibers Bundles Clusters Struct. Struct > = 5um 'Struct/mm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 q 0 0.0 o.ooo'o 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

TVnbiguous 0 ’ 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures)- 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is- in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITy_21MC100_011107752

NYC-WTC_000270751

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270751Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270883

TEM analysis; exterior & interior, sample 16.

Similar indexed content

NYC-WTC_000270668

TEM analysis of asbestos fibers at New Stuyvesant HS with SAED/EDS, Oct 2001.

Similar indexed content

NYC-WTC_000270539

TEM asbestos analysis for exterior/interior of New Stuyvesant H.S.; includes sample numbers and date.

Similar indexed content

NYC-WTC_000270552

TEM asbestos analysis with SAED for New Stuyvesant H.S.; includes sample numbers and date.

Similar indexed content

Compare copies and versions →