NYC-WTC_000270979
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗TEM/SAED/EDS analysis results for Stuyvesant High School project.
NYC-WTC_000293355OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/04/01
ASBESTOS FIBER TkNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CPR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 559B - 59979 Outside Building Date Received: 10/04/01 Grid Openings Analyzed;__ 4
Project Sample No.:_03 Average Grid Opening: 106.00 um
Air Volume: 1853 liters Total Area Analyzed: 0.0450 mTn2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2 Effective Area :^85 mrn2 0.0046 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct. >e5um Struct/mm2 Struct/cc ngrn/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Thialysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003081992
NYC-WTC_000293355
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270979
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270131
TEM asbestos analysis at Stuyvesant High School; SAED/EDS methods used for fiber identification.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293494
TEM data including air volume and EDS for NSHS samples.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294008
TEM analysis of air samples at New Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188696
Laboratory report presenting transmission electron microscopy results for asbestos fibers collected during an inspection of a high school.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293900
TEM analysis with structure ID and EDS; exterior/interior building data.
8 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270193
TEM analysis with SAED/EDS for Stuyvesant High School project.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270858
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293970
TEM analysis; New Stuyvesant HS project; received 10/26/01.
8 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182602
Technical data sheet recording air volume and microscopic analysis parameters for exterior and interior samples at Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293806
Asbestos TEM analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270973
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000270979
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270131
TEM asbestos analysis at Stuyvesant High School; SAED/EDS methods used for fiber identification.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293494
TEM data including air volume and EDS for NSHS samples.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294008
TEM analysis of air samples at New Stuyvesant H.S., Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188696
Laboratory report presenting transmission electron microscopy results for asbestos fibers collected during an inspection of a high school.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293900
TEM analysis with structure ID and EDS; exterior/interior building data.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.
Similar indexed content
NYC-WTC_000270131
TEM asbestos analysis at Stuyvesant High School; SAED/EDS methods used for fiber identification.
Similar indexed content
NYC-WTC_000293494
TEM data including air volume and EDS for NSHS samples.
Similar indexed content
TEM analysis of air samples at New Stuyvesant H.S., Oct 2001.
Similar indexed content
NYC-WTC_000188696
Laboratory report presenting transmission electron microscopy results for asbestos fibers collected during an inspection of a high school.
Similar indexed content