NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 34 pages

Guidance for Environments, NYC WTC

Machine-extracted title · confidence 35%

Guidance document related to environmental health at World Trade Center site.

NYC-WTC_000291428–000291461
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Protection from Chemical, Biological, or Radiological Attacks [9

architecturally com­ patible design. The goal is to minimize public accessibility. In general, this means the higher the exten­ sions, the better—as long as other design constraints (excessive pressure loss, dynamic IK and static loads on structure) are appro SO priately considered. An extension height of 12 feet (3.7 m) will place ===== the intake out of reach j of individuals without ■I L ” some assistance. Also, the entrance to the BSIK intake should be cov­ ered with a sloped metal mesh to reduce the threat of objects being tossed into the intake. A minimum slope of 45" is generally adequate. Extension height should be increased where existing platforms or building features (i.e., .4" loading docks, retaining walls) might provide access to the ft outdoor air intakes.

Establish a security zone around outdoor air intakes. Physically inaccessible outdoor air intakes are the preferred protection strategy. When outdoor air intakes are publicly accessible and relocation or physical extensions are not viable options, perimeter barriers that prevent public access to out­ door air intake areas may be an effective alternative. Iron

CITY_21MC100_011104380

NYC-WTC_000291444

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000291444Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000127738 · Box DEP Box 52

Health and safety plan for Phase I deconstruction at 133-135 Greenwich Street and 21-23 Thames Street dated June 8, 2005.

Similar indexed content

NYC-WTC_000279102

Building Department memo/guide related to emergency planning after 9/11.

Similar indexed content

Compare copies and versions →